Pneumatic rack-and-pinion
Trunnion ball valve on spring fail-close
A trunnion ball must isolate when air fails. Its spring pack finishes the close stroke at the minimum spring output.
Inputs
Results
Edit inputs- Breakaway
- 855in-lb
- Seating
- 735in-lb
- Min. piston
- 3.8in
- Worst margin
- 165in-lb
Air and return strokes meet the factored torque points at the selected supply pressure.
Demand and actuator torque
All calculated values
| Factored breakaway torque | 855 in-lb |
|---|---|
| Factored seating torque | 735 in-lb |
| Factored running torque | 465 in-lb |
| Applied pressure torque multiplier | 1 × |
| Supply pressure | 100 psig |
| Gross air torque | 2,144.66 in-lb |
| Minimum equivalent piston bore | 3.799 in |
| Air stroke direction | Opening |
| Return stroke direction | Closing |
| Air stroke start output | 1,244.66 in-lb |
| Air stroke end output | 894.66 in-lb |
| Return stroke start output | 1,250 in-lb |
| Return stroke end output | 900 in-lb |
| Air start torque margin | 389.66 in-lb |
| Air end torque margin | 429.66 in-lb |
| Return start torque margin | 785 in-lb |
| Return end torque margin | 165 in-lb |
| Worst stroke margin | 165 in-lb |
| Stem margin at selected pressure | 1,350 in-lb |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Factor the breakaway demand855 in-lb
- Find the equivalent air-side bore3.799 in
- Check the worst stroke point165 in-lb
Review the air-open and spring-close points independently, including seating at spring end and the maximum output against the stem limit.
Model and limits
Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.
Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.
View equations and references