Pneumatic rack-and-pinion

Floating ball valve with double-acting air

A floating-ball isolation valve uses OEM torque inputs at the stated differential and an 80 psig minimum supply.

Inputs

Valve torque basis
Actuator geometry
Breakaway
855in-lb
Seating
735in-lb
Min. piston
3.14in
Worst margin
328.6in-lb
Stroke torque margins available

Air and return strokes meet the factored torque points at the selected supply pressure.

Demand and actuator torque

Demand and actuator torqueTorque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.06391,278in-lb0°STROKE90°AIR BOTH WAYSOPEN DEMANDCLOSE DEMANDMIN. AIR1,184 in-lbMIN. RETURN1,184 in-lbWORST MARGIN329 in-lb
Torque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.

All calculated values
Factored breakaway torque855 in-lb
Factored seating torque735 in-lb
Factored running torque465 in-lb
Applied pressure torque multiplier1 ×
Supply pressure80 psig
Gross air torque1,183.59 in-lb
Minimum equivalent piston bore3.145 in
Air stroke directionOpening
Return stroke directionClosing
Air stroke start output1,183.59 in-lb
Air stroke end output1,183.59 in-lb
Return stroke start output1,183.59 in-lb
Return stroke end output1,183.59 in-lb
Air start torque margin328.59 in-lb
Air end torque margin718.59 in-lb
Return start torque margin718.59 in-lb
Return end torque margin448.59 in-lb
Worst stroke margin328.59 in-lb
Stem margin at selected pressure1,416.41 in-lb

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Factor the breakaway demand855 in-lb
  2. Find the equivalent air-side bore3.145 in
  3. Check the worst stroke point328.59 in-lb

A double-acting actuator is checked in both directions against factored breakaway, running and seating points.

Model and limits

Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.

Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.

View equations and references

Worked examples