Pneumatic rack-and-pinion

Oversized actuator versus stem torque limit

A larger actuator was proposed for a valve with a limited maximum allowable stem torque.

Inputs

Valve torque basis
Actuator geometry
Breakaway
80.5N·m
Seating
69.2N·m
Min. piston
58.8mm
Worst margin
301N·m
Stem torque limit exceeded

At least one actuator output exceeds the entered stem torque limit.

Demand and actuator torque

Demand and actuator torqueTorque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.0206412N·m0°STROKE90°AIR BOTH WAYSOPEN DEMANDCLOSE DEMANDMIN. AIR382 N·mMIN. RETURN382 N·mWORST MARGIN301 N·m
Torque is plotted against stroke progress in each direction. Compare available output with each direction’s demand.

All calculated values
Factored breakaway torque80.5 N·m
Factored seating torque69.2 N·m
Factored running torque43.78 N·m
Applied pressure torque multiplier1 ×
Supply pressure6.89 bar g
Gross air torque381.5 N·m
Minimum equivalent piston bore58.798 mm
Air stroke directionOpening
Return stroke directionClosing
Air stroke start output381.5 N·m
Air stroke end output381.5 N·m
Return stroke start output381.5 N·m
Return stroke end output381.5 N·m
Air start torque margin301 N·m
Air end torque margin337.72 N·m
Return start torque margin337.72 N·m
Return end torque margin312.3 N·m
Worst stroke margin301 N·m
Stem margin at selected pressure-141.5 N·m

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Factor the breakaway demand80.5 N·m
  2. Find the equivalent air-side bore58.798 mm
  3. Check the worst stroke point301 N·m

An actuator may deliver more than the stem can withstand even when it clears stroke demand. Review the maximum possible supply with the OEM.

Model and limits

Enter OEM breakaway, running and seating torque at the reference differential. Demand uses a service multiplier and a provisional valve-type correction of the form b + (1 − b) ΔP/ΔPref. Base fractions b are 0.35 for floating ball, 0.55 for trunnion, 0.50 for butterfly and 0.65 for plug.

Set the reference differential to the service differential when using OEM torque data for that duty. The equivalent bore assumes two equal pistons and constant pitch radius. It sizes the air side only. Use vendor start, mid-stroke and end torque tables for both directions, minimum air available while stroking, stem limits at maximum supply, and the actual fail-safe spring set.

View equations and references

Worked examples