Concrete Vc
32.63 kip
Stirrup Vs
35.48 kip
φVn
51.08 kip
Spacing max
10.75 in
Anatomy Diagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 12 in s 8 in Vs 35.48 kip
Screening Within screening limits
Shear utilization 94%
Table 22.5.5.1(a) 6% below the threshold
Shear strength Vu ≤ φ(Vc + Vs, credited)
Within limit Diagonal compression Required Vs ≤ 8√f′c bw d
Within limit Minimum stirrup area Av ≥ Av,min when Vu > φλ√f′c bw d
Within limit Stirrup spacing Longitudinal spacing ≤ smax
Within limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.
Calculation readout Quantity Value
Concrete shear Vc 32.63 kip Provided stirrup Vs 35.48 kip Design shear φVn 51.08 kip Maximum stirrup spacing 10.75 in Minimum stirrup area Av,min 0.08 in² Minimum steel demand trigger 12.24 kip Required stirrup Vs 31.37 kip Diagonal compression Vs cap 130.54 kip Size effect λs (applied) 1 Longitudinal ratio ρw 0.919 % Axial stress contribution 0 psi Transverse yield used 60 ksi
Share link
Reset defaults
JSON
CSV
SVG
PNG ×2
Print A4
Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).
RebarStructLab • ACI 318-19 • US
§9.6 / §9.7 / §22.5
Concrete Beam One-Way Shear Calculator
Vertical stirrups · rectangular web · Within screening limits
Inputs
Web width bw 12 in
Overall depth h 24 in
Effective depth d 21.5 in
Longitudinal steel As 2.37 in²
Axial Nu (+ compression) 0 kip
Factored shear Vu 48 kip
Concrete strength f′c 4,000 psi
Lightweight factor λ 1
Leg area Av 0.22 in²
Stirrup spacing s 8 in
Transverse yield fyt 60 ksi
Calculated values
Concrete shear Vc 32.63 kip
Provided stirrup Vs 35.48 kip
Design shear φVn 51.08 kip
Maximum stirrup spacing 10.75 in
Minimum stirrup area Av,min 0.08 in²
Minimum steel demand trigger 12.24 kip
Required stirrup Vs 31.37 kip
Diagonal compression Vs cap 130.54 kip
Size effect λs (applied) 1
Longitudinal ratio ρw 0.919 %
Axial stress contribution 0 psi
Transverse yield used 60 ksi
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 12 in s 8 in Vs 35.48 kip
Screening
Table 22.5.5.1(a) · Shear utilization 94%
Shear strength · Within limitDiagonal compression · Within limitMinimum stirrup area · Within limitStirrup spacing · Within limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.