ACI 318-19 §9.6 / §9.7 / §22.5

Axial compression and the shear stress cap

A combined axial compression and shear case exercises the cap on Nu/(6Ag).

Edit inputs ↓

Inputs

Editable example

Section & loads
Materials & stirrups
Concrete Vc 81.59kip
Stirrup Vs 35.48kip
φVn 87.8kip
Spacing max 10.75in
AnatomyDiagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale. STIRRUP ELEVATIONdbw 12 ins 8 inVs 35.48 kip

Screening

Within screening limits
Shear utilization70.6%
Table 22.5.5.1(a)29.4% below the threshold
  • Shear strengthVu ≤ φ(Vc + Vs, credited)
    Within limit
  • Diagonal compressionRequired Vs ≤ 8√f′c bw d
    Within limit
  • Minimum stirrup areaAv ≥ Av,min when Vu > φλ√f′c bw d
    Within limit
  • Stirrup spacingLongitudinal spacing ≤ smax
    Within limit

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

Calculation readout
QuantityValue
Concrete shear Vc81.59 kip
Provided stirrup Vs35.48 kip
Design shear φVn87.8 kip
Maximum stirrup spacing10.75 in
Minimum stirrup area Av,min0.08 in²
Minimum steel demand trigger12.24 kip
Required stirrup Vs1.08 kip
Diagonal compression Vs cap130.54 kip
Size effect λs (applied)1
Longitudinal ratio ρw0.919 %
Axial stress contribution200 psi
Transverse yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Axial Nu (+ compression)
550 kip
Factored shear Vu
62 kip

Calculated result

Concrete shear Vc
81.59 kip
Provided stirrup Vs
35.48 kip
Design shear φVn
87.8 kip
Maximum stirrup spacing
10.75 in

Compute the axial stress contribution with the gross web area. The upper bound limits its credit before calculating Vc.

Preset screening · Table 22.5.5.1(a) · Within limits

How the check works

Code basis ↗
  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).