ACI 318-19 §25.3 / §25.4 / §25.5

Rebar Development & Lap Splice Calculator

Size straight tension embedment, standard 90° and 180° hooks, and a Class B tension lap splice.

Edit inputs ↓

Inputs

Deformed tension bars · standard hooks

Bar & bond
Available geometry
Straight ℓd 17.08in
Hook ℓdh 12.14in
Class B lap 22.2in
Confinement 2.5 
AnatomyDiagrammatic scale
Parameter-linked development drawing. Diagrammatic scale. STRAIGHT BAR DEVELOPMENTRequired embedmentdb 0.75 inNeed 17.08 inHave 32 in

Screening

Within screening limits
Required / available length53.4%
Straight tension bar46.6% below the threshold
  • Available embedmentAvailable length ≥ required length for the selected detail
    Within limit

Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.

Calculation readout
QuantityValue
Straight development ℓd17.08 in
Hook development ℓdh12.14 in
Class B with 1.3 × floored ℓd22.2 in
Confinement (cᵦ + Ktr)/db2.5
Nominal bar diameter db0.75 in
Spacing/cover term cᵦ2.375 in
Selected required length17.08 in
Class B minimum per §25.5.222.2 in
Minimum inside bend diameter4.5 in
90° straight tail9 in
180° straight tail3 in
Top cast ψt1
Epoxy ψe (straight)1
Size ψs0.8
Grade ψg1
Hook confinement ψr1
Hook location ψo1.25
Hook concrete ψc0.867

How the check works

Code basis ↗
  1. Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
  2. Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
  3. Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.