5- vs 6-inch K-style gutter on a short eave

A 32 ft eave handles 1,200 ft² of 6:12 roof at 6 in/hr, with one large round outlet in the initial layout.

Worked calculation

The sizing flow is about 82.3 gal/min. Under the reference assumptions, one outlet and one 6-inch K-style reach meet the screen.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Contributing roof and storm
ft²
:12
Gutter and outlets
ft
ft
Capacity overrides
US gal/min Zero uses the profile’s reference capacity.
US gal/min Enter the manufacturer’s flow for your actual slope and run.
US gal/min Zero uses the screening value for the selected profile.

Results

Live

Gutter reaches and downspout flowEstimated gutter width 6 in. Downspouts for selected layout 1. K-STYLE GUTTER6 in nominal1 downspout82.29 US gal/min each32 ft eave length per outlet
Gutter reaches and downspout flow Schematic
Adjusted drainage area
1,320 ft²
Pitch allowance
1.1×
Peak runoff from projected area
74.81 US gal/min
Peak runoff, alternate units
0.1667 ft³/s
Sizing flow with pitch allowance
82.29 US gal/min
Sizing flow per outlet
82.29 US gal/min
Average eave length per outlet
32 ft
5 in / 127 mm reference
60 US gal/min
6 in / 152 mm reference
90 US gal/min
Selected outlet assembly capacity
90 US gal/min
2 × 3 in / 51 × 76 mm leader minimum
3
3 × 4 in / 76 × 102 mm leader minimum
2
4 in / 102 mm round leader minimum
1

Apply this example to your roof

Half-round defaults use the 2021 IPC semicircular reference at 1/8 in/ft. K-style defaults of 60 and 90 gal/min and leader assembly defaults of 30, 60 and 90 gal/min are screening assumptions. Replace them with documented ratings for your slope, outlets and profiles. Check concentrated valley flow, walls that contribute runoff and overflow paths.

Read the calculator method and references

Frequently asked questions

Why does the short K-style eave screen at 6 inches?

Its adjusted flow is above the 5-inch planning assumption of 60 gal/min and below the 6-inch assumption of 90 gal/min.

What would a second outlet change on the short eave?

If both reaches get equal area, each would handle about 41 gal/min. Check the actual catchment split before sizing the gutter.