Rain Gutter Sizing & Downspout Capacity Calculator
Estimate peak roof runoff, compare 5- and 6-inch profiles and split an eave into downspout reaches.
Results
LiveCorrect the highlighted inputs to update your results.
- Estimated gutter width
- Downspouts for selected layout
- Adjusted drainage area
- Pitch allowance
- Peak runoff from projected area
- Peak runoff, alternate units
- Sizing flow with pitch allowance
- Sizing flow per outlet
- Average eave length per outlet
- 5 in / 127 mm reference
- 6 in / 152 mm reference
- Selected outlet assembly capacity
- 2 × 3 in / 51 × 76 mm leader minimum
- 3 × 4 in / 76 × 102 mm leader minimum
- 4 in / 102 mm round leader minimum
Worksheet inputs US customary
- Projected area draining to this gutter
- 1,600 ft²
- Contributing roof pitch
- 6:12
- Peak rainfall intensity
- 6 in/hr
- Continuous eave run
- 48 ft
- Maximum length served per outlet
- 35 ft
- Gutter profile
- K-style
- Downspout profile
- 2 × 3 in rectangular
- 5 in / 127 mm gutter capacity
- 0 US gal/min
- 6 in / 152 mm gutter capacity
- 0 US gal/min
- Selected outlet assembly capacity
- 0 US gal/min
Size the gutter and its outlets together
- Enter the horizontal project area that drains to this eave. Peak roof flow in US gal/min is area in ft² × intensity in in/hr × (144 ÷ 231) ÷ 60. The pitch allowance is a separate sizing factor.
- Pitch bands below 4, 6, 9 and 12 use 1.00, 1.05, 1.10 and 1.20. At 12:12 and steeper the factor is 1.30. Preset storms are sensitivity cases. Enter a locally approved design rate for a project.
- The tool splits flow and length evenly across reaches. It considers outlet capacity, maximum eave length per outlet and the larger gutter rating, then chooses 5 inches if the resulting flow fits that profile.
Half-round defaults use the 2021 IPC semicircular reference at 1/8 in/ft. K-style defaults of 60 and 90 gal/min and leader assembly defaults of 30, 60 and 90 gal/min are screening assumptions. Replace them with documented ratings for your slope, outlets and profiles. Check concentrated valley flow, walls that contribute runoff and overflow paths.
References
Frequently asked questions
How do I find the rainfall rate for a roof gutter estimate?
Use the duration and return period required by the applicable drainage rules. Regional precipitation-frequency data can help establish the rate.
Why are peak roof runoff and sizing flow shown separately?
Peak runoff uses the horizontal area. Sizing flow applies the selected empirical pitch allowance before comparing with gutter and outlet capacities.
What does average eave length per outlet tell me?
It divides the continuous eave evenly among the suggested outlets. Confirm actual gutter high points, outlet locations and tributary areas in the layout.