Tapered insulation over a backfall deck

A survey shows the deck falls away from the drain by 0.30 in/ft. Test a proposed 1/4 in/ft insulation taper.

Worked calculation

Add the signed deck slope to the board slope. The net surface slope is −0.05 in/ft, so the top still falls away from the drain by an inch over the run.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Drainage zone
ft²
ft
in/ft Use a negative value when the deck falls away from the drain.
in
Optional diamond cricket
ft Set the length to zero to omit the cricket.

Results

Live

Tapered insulation section and cricketThick end of main taper 7 in. Total insulation volume 5,175 board ft. INSULATION SECTION5,175 board ft totalThick 7 inDrain 2 inRun 20 ftNet slope -0.05 in/ft
Tapered insulation section and cricket Schematic
Insulation rise
5 in
Net surface slope toward drain
-0.05 in/ft
Net surface fall to drain
-1 in
Average main-taper thickness
4.5 in
Thermal resistance per thickness
5.7 R/in
Thin-end insulation R-value
11.4 h·ft²·°F/Btu
Arithmetic average insulation R-value
25.65 h·ft²·°F/Btu
Idealized effective insulation R-value
22.75 h·ft²·°F/Btu
Main taper volume
5,175 board ft
Cricket projected area
0 ft²
Cricket add-on peak rise
0 in
Cricket add-on volume
0 board ft
  • Ponding risk: the proposed roof surface has zero or adverse fall toward the drain.

Apply this example to your roof

Verify roof assembly slope and thermal requirements, low spots, flashing clearance, tapered board layouts and secondary drainage. The R-value is for the modeled insulation. The arithmetic average does not describe the thin-end R-value.

Read the calculator method and references

Frequently asked questions

Why is the output slope negative with a positive taper board?

The adverse deck slope is steeper than the board slope. The finished surface still falls away from the drain.

Do thicker flat boards fix this surveyed backfall?

An even layer raises both ends by the same amount. A changed taper or drain layout is needed to change the net slope.