Tapered insulation over a backfall deck
A survey shows the deck falls away from the drain by 0.30 in/ft. Test a proposed 1/4 in/ft insulation taper.
Worked calculation
Add the signed deck slope to the board slope. The net surface slope is −0.05 in/ft, so the top still falls away from the drain by an inch over the run.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Thick end of main taper
- Total insulation volume
- Insulation rise
- Net surface slope toward drain
- Net surface fall to drain
- Average main-taper thickness
- Thermal resistance per thickness
- Thin-end insulation R-value
- Arithmetic average insulation R-value
- Idealized effective insulation R-value
- Main taper volume
- Cricket projected area
- Cricket add-on peak rise
- Cricket add-on volume
- Ponding risk: the proposed roof surface has zero or adverse fall toward the drain.
Worksheet inputs US customary
- Horizontal drainage zone area
- 1,150 ft²
- Horizontal run to drain
- 20 ft
- Tapered board slope
- 1/4 in/ft
- Existing deck slope to drain
- -0.3 in/ft
- Thin insulation at drain
- 2 in
- Insulation board
- Polyiso · nominal
- Cricket tip-to-tip length
- 0 ft
Apply this example to your roof
Verify roof assembly slope and thermal requirements, low spots, flashing clearance, tapered board layouts and secondary drainage. The R-value is for the modeled insulation. The arithmetic average does not describe the thin-end R-value.
Frequently asked questions
Why is the output slope negative with a positive taper board?
The adverse deck slope is steeper than the board slope. The finished surface still falls away from the drain.
Do thicker flat boards fix this surveyed backfall?
An even layer raises both ends by the same amount. A changed taper or drain layout is needed to change the net slope.