Tapered roof R-value using a product rating
A product submittal gives R-5.4 per inch. The taper rises from 3 inches at 1/4 in/ft over 14 feet.
Worked calculation
The thick end is 6.5 inches and the arithmetic average thickness is 4.75 inches. Multiply by 5.4 for average R-25.65. The effective result models heat flowing through varying thicknesses.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Thick end of main taper
- Total insulation volume
- Insulation rise
- Net surface slope toward drain
- Net surface fall to drain
- Average main-taper thickness
- Thermal resistance per thickness
- Thin-end insulation R-value
- Arithmetic average insulation R-value
- Idealized effective insulation R-value
- Main taper volume
- Cricket projected area
- Cricket add-on peak rise
- Cricket add-on volume
Worksheet inputs US customary
- Horizontal drainage zone area
- 860 ft²
- Horizontal run to drain
- 14 ft
- Tapered board slope
- 1/4 in/ft
- Existing deck slope to drain
- 0 in/ft
- Thin insulation at drain
- 3 in
- Insulation board
- Enter product R-value
- Product thermal resistance per thickness
- 5.4 R/in
- Cricket tip-to-tip length
- 0 ft
Apply this example to your roof
Verify roof assembly slope and thermal requirements, low spots, flashing clearance, tapered board layouts and secondary drainage. The R-value is for the modeled insulation. The arithmetic average does not describe the thin-end R-value.
Frequently asked questions
Why is the effective R below the arithmetic average in this case?
Heat flows more readily through the thinner sections. The effective model averages parallel heat paths across a uniformly wide tapered zone.
Does the 5.4 product rating include the roof membrane and cover board?
It is the entered insulation rating only. Add other layers using the project assembly method.