Half-inch EPS taper on a short roof
A small utility roof has a 10 ft run to a scupper. Use a 1/2 in/ft EPS taper with 1.5 inches at the drain.
Worked calculation
The board gains 5 inches over the run and reaches 6.5 inches. At 4 R per inch, the 1.5-inch thin edge gives a nominal R-6.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Thick end of main taper
- Total insulation volume
- Insulation rise
- Net surface slope toward drain
- Net surface fall to drain
- Average main-taper thickness
- Thermal resistance per thickness
- Thin-end insulation R-value
- Arithmetic average insulation R-value
- Idealized effective insulation R-value
- Main taper volume
- Cricket projected area
- Cricket add-on peak rise
- Cricket add-on volume
Worksheet inputs US customary
- Horizontal drainage zone area
- 310 ft²
- Horizontal run to drain
- 10 ft
- Tapered board slope
- 1/2 in/ft
- Existing deck slope to drain
- 0 in/ft
- Thin insulation at drain
- 1.5 in
- Insulation board
- EPS · nominal
- Cricket tip-to-tip length
- 0 ft
Apply this example to your roof
Verify roof assembly slope and thermal requirements, low spots, flashing clearance, tapered board layouts and secondary drainage. The R-value is for the modeled insulation. The arithmetic average does not describe the thin-end R-value.
Frequently asked questions
Where does the short EPS roof reach its minimum R-value?
At the thin edge by the scupper. Compare the 1.5-inch thickness with the selected product’s rating and applicable energy requirements.
Is the utility roof’s assumed R-4 per inch universal for EPS?
EPS density, thickness and test conditions vary by product. Enter the documented value for a project takeoff.