Half-inch EPS taper on a short roof

A small utility roof has a 10 ft run to a scupper. Use a 1/2 in/ft EPS taper with 1.5 inches at the drain.

Worked calculation

The board gains 5 inches over the run and reaches 6.5 inches. At 4 R per inch, the 1.5-inch thin edge gives a nominal R-6.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Drainage zone
ft²
ft
in/ft Use a negative value when the deck falls away from the drain.
in
Optional diamond cricket
ft Set the length to zero to omit the cricket.

Results

Live

Tapered insulation section and cricketThick end of main taper 6.5 in. Total insulation volume 1,240 board ft. INSULATION SECTION1,240 board ft totalThick 6.5 inDrain 1.5 inRun 10 ftNet slope 0.5 in/ft
Tapered insulation section and cricket Schematic
Insulation rise
5 in
Net surface slope toward drain
0.5 in/ft
Net surface fall to drain
5 in
Average main-taper thickness
4 in
Thermal resistance per thickness
4 R/in
Thin-end insulation R-value
6 h·ft²·°F/Btu
Arithmetic average insulation R-value
16 h·ft²·°F/Btu
Idealized effective insulation R-value
13.64 h·ft²·°F/Btu
Main taper volume
1,240 board ft
Cricket projected area
0 ft²
Cricket add-on peak rise
0 in
Cricket add-on volume
0 board ft

Apply this example to your roof

Verify roof assembly slope and thermal requirements, low spots, flashing clearance, tapered board layouts and secondary drainage. The R-value is for the modeled insulation. The arithmetic average does not describe the thin-end R-value.

Read the calculator method and references

Frequently asked questions

Where does the short EPS roof reach its minimum R-value?

At the thin edge by the scupper. Compare the 1.5-inch thickness with the selected product’s rating and applicable energy requirements.

Is the utility roof’s assumed R-4 per inch universal for EPS?

EPS density, thickness and test conditions vary by product. Enter the documented value for a project takeoff.