Quarter-inch polyiso taper across 24 ft

A 1,600 ft² flat deck drains over 24 ft with a 1/4 in/ft taper, 2 inches at the drain and a small diamond cricket.

Worked calculation

The main field rises 6 inches, from 2 to 8. Its average is 5 inches for 8,000 board ft, with a further 18 board ft from the cricket.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Drainage zone
ft²
ft
in/ft Use a negative value when the deck falls away from the drain.
in
Optional diamond cricket
ft Set the length to zero to omit the cricket.
ft
in/ft

Results

Live

Tapered insulation section and cricketThick end of main taper 8 in. Total insulation volume 8,018 board ft. INSULATION SECTION8,018 board ft totalThick 8 inDrain 2 inRun 24 ftNet slope 0.25 in/ftCricket +1.5 in
Tapered insulation section and cricket Schematic
Insulation rise
6 in
Net surface slope toward drain
0.25 in/ft
Net surface fall to drain
6 in
Average main-taper thickness
5 in
Thermal resistance per thickness
5.7 R/in
Thin-end insulation R-value
11.4 h·ft²·°F/Btu
Arithmetic average insulation R-value
28.5 h·ft²·°F/Btu
Idealized effective insulation R-value
24.67 h·ft²·°F/Btu
Main taper volume
8,000 board ft
Cricket projected area
36 ft²
Cricket add-on peak rise
1.5 in
Cricket add-on volume
18 board ft
Cricket center-to-tip ridge slope
0.25 in/ft

Apply this example to your roof

Verify roof assembly slope and thermal requirements, low spots, flashing clearance, tapered board layouts and secondary drainage. The R-value is for the modeled insulation. The arithmetic average does not describe the thin-end R-value.

Read the calculator method and references

Frequently asked questions

How high does the quarter-inch taper get over 24 feet?

It adds 6 inches to the 2-inch drain thickness, putting the thick end at 8 inches.

Why is the cricket volume added to the polyiso field volume?

The scenario treats it as a separate wedge above the continuous main taper. Its peak is localized.