RoomAcousticLab · Calculation record
Reverberation time example
Cool atrium decay
Use the sound-speed correction for a cool atrium. Screen a deliberately tight target against the feasible treatment area of the chosen orientation.
Inputs
Use absorption coefficients for the same frequency band.
- Sabine
- 3.515s
- Eyring
- 3.353s
- Fitzroy
- 3.77s
- Panel area
- —
Room section & absorption
Illustrative scaleTarget infeasible on selected faces
LimitEven replacing both faces in this orientation cannot reach the target with the selected panel and model.
Target metPanels neededInfeasible
Input snapshot
- Length
- 18 m
- Width
- 11 m
- Height
- 9 m
- End walls αx
- 0.05
- Side walls αy
- 0.08
- Floor / ceiling αz
- 0.12
- Air temperature
- 8 °C
- Target RT60
- 0.42 s
- Size panels with
- Eyring
- Treatment surface
- Floor / ceiling · z
- Panel absorption α
- 0.85
- Available area
- 100 m²
Calculation breakdown
- Room volume
- 1,782 m³
- Room surface area
- 918 m²
- Equivalent absorption area
- 83.34 m²
- Mean absorption α
- 0.0908
- Treatment sizing model
- Eyring
- Baseline α of selected pair
- 0.12
- Selected pair area
- 396 m²
- Decay before treatment
- 3.353 s
- Decay with proposed area
- No feasible area
- Best decay within allowance
- 1.709 s
Use Sabine in the low-absorption regime, Eyring for a more evenly distributed field, and Fitzroy when opposite pairs differ. The models omit air absorption, leakage and non-diffuse geometry. Measured decay and installed band coefficients should drive a final specification.