Reverberation time example

Cool atrium decay

Use the sound-speed correction for a cool atrium. Screen a deliberately tight target against the feasible treatment area of the chosen orientation.

Inputs

Room geometry
Surface absorption
Treatment plan

Use absorption coefficients for the same frequency band.

Sabine
3.515s
Eyring
3.353s
Fitzroy
3.77s
Panel area
—

Room section & absorption

Illustrative scale
Dimensioned room and treatment surfaceThe selected pair of surfaces is highlighted beside its absorption coefficient. A sample reflection links room geometry to decay.L 18 mW 11 mH 9 mPAIR ABSORPTIONαx 0.05αy 0.08αz 0.12PANEL COVERAGEInfeasible
TreatmentReflectionsDimensions

Target infeasible on selected faces

Limit

Even replacing both faces in this orientation cannot reach the target with the selected panel and model.

Target metPanels neededInfeasible

Calculation breakdown

Room volume
1,782 m³
Room surface area
918 m²
Equivalent absorption area
83.34 m²
Mean absorption α
0.0908
Treatment sizing model
Eyring
Baseline α of selected pair
0.12
Selected pair area
396 m²
Decay before treatment
3.353 s
Decay with proposed area
No feasible area
Best decay within allowance
1.709 s