Reverberation time example

Boardroom wall panels

Compare three decay estimates in a glass-fronted meeting room and size end-wall panels with the Fitzroy model.

Inputs

Room geometry
Surface absorption
Treatment plan

Use absorption coefficients for the same frequency band.

Sabine
0.653s
Eyring
0.59s
Fitzroy
0.808s
Panel area
3.09m²

Room section & absorption

Illustrative scale
Dimensioned room and treatment surfaceThe selected pair of surfaces is highlighted beside its absorption coefficient. A sample reflection links room geometry to decay.L 7.5 mW 5 mH 3 mPAIR ABSORPTIONαx 0.06αy 0.16αz 0.25PANEL COVERAGE10.3% of pair
TreatmentReflectionsDimensions

Target reachable with panels

Review

The calculated area fits the entered allowance. Verify the installed absorption for the same band.

Target metPanels neededInfeasible

Calculation breakdown

Room volume
112.5 m³
Room surface area
150 m²
Equivalent absorption area
27.75 m²
Mean absorption α
0.185
Treatment sizing model
Fitzroy
Baseline α of selected pair
0.06
Selected pair area
30 m²
Decay before treatment
0.808 s
Decay with proposed area
0.57 s
Best decay within allowance
0.466 s