Room modes & Schroeder frequency

Rank rectangular-room eigenmodes and screen low-frequency spacing, proportions and modal density.

Inputs

Room geometry
Decay & air
First mode
26.8Hz
Schroeder
135.7Hz
Largest gap
10.5Hz
Coincidences
1

Standing waves & modal spectrum

Illustrative scale
Room plan and modal spectrumThe room plan illustrates standing-wave contours. Spectral lines show the first 18 modes with different heights and colours for their three families.ROOM PLANLOWEST 18 MODESL 6.4 mW 4.6 m26.8 Hz96.7 HzSchroeder 135.7 Hz
AxialTangentialOblique

Several modal screening flags

Limit

Review the ratio, coincidences, gaps and band counts before settling the dimensions.

Clear screenReviewMultiple flags

Calculation breakdown

Room volume
91.26 m³
Sound speed
343.2 m/s
H : W : L proportions
1 : 1.484 : 2.065
Approximate Bolt area
Inside
Bonello density screen
Review
Gap review threshold
20 Hz
Lowest 24 eigenmodes
ModeFamilyFrequency
(1, 0, 0)axial26.81 Hz
(0, 1, 0)axial37.31 Hz
(1, 1, 0)tangential45.94 Hz
(2, 0, 0)axial53.63 Hz
(0, 0, 1)axial55.36 Hz
(1, 0, 1)tangential61.51 Hz
(2, 1, 0)tangential65.33 Hz
(0, 1, 1)tangential66.75 Hz
(1, 1, 1)oblique71.94 Hz
(0, 2, 0)axial74.61 Hz
(2, 0, 1)tangential77.07 Hz
(1, 2, 0)tangential79.28 Hz
(3, 0, 0)axial80.44 Hz
(2, 1, 1)oblique85.63 Hz
(3, 1, 0)tangential88.67 Hz
(2, 2, 0)tangential91.88 Hz
(0, 2, 1)tangential92.91 Hz
(1, 2, 1)oblique96.7 Hz
(3, 0, 1)tangential97.65 Hz
(3, 1, 1)oblique104.53 Hz
(4, 0, 0)axial107.25 Hz
(2, 2, 1)oblique107.27 Hz
(3, 2, 0)tangential109.72 Hz
(0, 0, 2)axial110.71 Hz
Bonello band counts below Schroeder
Band centreModesCoincidence
20 Hz0—
25 Hz1—
31.5 Hz0—
40 Hz1—
50 Hz3—
63 Hz3—
80 Hz7—
100 Hz10Yes