RoomAcousticLab · Calculation record
Room modes & Schroeder frequency
Rank rectangular-room eigenmodes and screen low-frequency spacing, proportions and modal density.
Inputs
- First mode
- 26.8Hz
- Schroeder
- 135.7Hz
- Largest gap
- 10.5Hz
- Coincidences
- 1
Standing waves & modal spectrum
Illustrative scaleSeveral modal screening flags
LimitReview the ratio, coincidences, gaps and band counts before settling the dimensions.
Clear screenReviewMultiple flags
Input snapshot
- Length
- 6.4 m
- Width
- 4.6 m
- Height
- 3.1 m
- Measured or predicted RT60
- 0.42 s
- Air temperature
- 20 °C
Calculation breakdown
- Room volume
- 91.26 m³
- Sound speed
- 343.2 m/s
- H : W : L proportions
- 1 : 1.484 : 2.065
- Approximate Bolt area
- Inside
- Bonello density screen
- Review
- Gap review threshold
- 20 Hz
| Mode | Family | Frequency |
|---|---|---|
| (1, 0, 0) | axial | 26.81 Hz |
| (0, 1, 0) | axial | 37.31 Hz |
| (1, 1, 0) | tangential | 45.94 Hz |
| (2, 0, 0) | axial | 53.63 Hz |
| (0, 0, 1) | axial | 55.36 Hz |
| (1, 0, 1) | tangential | 61.51 Hz |
| (2, 1, 0) | tangential | 65.33 Hz |
| (0, 1, 1) | tangential | 66.75 Hz |
| (1, 1, 1) | oblique | 71.94 Hz |
| (0, 2, 0) | axial | 74.61 Hz |
| (2, 0, 1) | tangential | 77.07 Hz |
| (1, 2, 0) | tangential | 79.28 Hz |
| (3, 0, 0) | axial | 80.44 Hz |
| (2, 1, 1) | oblique | 85.63 Hz |
| (3, 1, 0) | tangential | 88.67 Hz |
| (2, 2, 0) | tangential | 91.88 Hz |
| (0, 2, 1) | tangential | 92.91 Hz |
| (1, 2, 1) | oblique | 96.7 Hz |
| (3, 0, 1) | tangential | 97.65 Hz |
| (3, 1, 1) | oblique | 104.53 Hz |
| (4, 0, 0) | axial | 107.25 Hz |
| (2, 2, 1) | oblique | 107.27 Hz |
| (3, 2, 0) | tangential | 109.72 Hz |
| (0, 0, 2) | axial | 110.71 Hz |
| Band centre | Modes | Coincidence |
|---|---|---|
| 20 Hz | 0 | — |
| 25 Hz | 1 | — |
| 31.5 Hz | 0 | — |
| 40 Hz | 1 | — |
| 50 Hz | 3 | — |
| 63 Hz | 3 | — |
| 80 Hz | 7 | — |
| 100 Hz | 10 | Yes |
Rigid rectangular boundaries give ideal eigenfrequencies. Construction details, source and listener placement, surface impedance and damping affect measured levels. The Schroeder frequency is an approximate crossover.