RoomAcousticLab · Calculation record
Reverberation time & panel area
Compare Sabine, Eyring and Fitzroy RT60, then size acoustic treatment for a target decay time.
Inputs
Use absorption coefficients for the same frequency band.
- Sabine
- 1.003s
- Eyring
- 0.93s
- Fitzroy
- 0.997s
- Panel area
- 14.12m²
Room section & absorption
Illustrative scaleTarget reachable with panels
ReviewThe calculated area fits the entered allowance. Verify the installed absorption for the same band.
Target metPanels neededInfeasible
Input snapshot
- Length
- 9 m
- Width
- 7 m
- Height
- 3.2 m
- End walls αx
- 0.09
- Side walls αy
- 0.12
- Floor / ceiling αz
- 0.17
- Air temperature
- 20 °C
- Target RT60
- 0.7 s
- Size panels with
- Eyring
- Treatment surface
- Floor / ceiling · z
- Panel absorption α
- 0.85
- Available area
- 48 m²
Calculation breakdown
- Room volume
- 201.6 m³
- Room surface area
- 228.4 m²
- Equivalent absorption area
- 32.36 m²
- Mean absorption α
- 0.1417
- Treatment sizing model
- Eyring
- Baseline α of selected pair
- 0.17
- Selected pair area
- 126 m²
- Decay before treatment
- 0.93 s
- Decay with proposed area
- 0.7 s
- Best decay within allowance
- 0.424 s
Use Sabine in the low-absorption regime, Eyring for a more evenly distributed field, and Fitzroy when opposite pairs differ. The models omit air absorption, leakage and non-diffuse geometry. Measured decay and installed band coefficients should drive a final specification.