Worked example · Controls & protection
Retail detention pond for a longer storm
A commercial watershed has a 60-minute design storm and a much shorter time of concentration, creating a broad inflow peak.
Inputs
Detention hydrograph
Live resultsBasin storage shortfall
Checks use the selected storm duration and report the outlet rating at the entered water depth.
Calculation results
- Storage req.
- 1.571 acre-ft
- Basin volume
- 1.226 acre-ft
- Outlet rating
- 6.95 cfs
- Storage reserve
- -0.345 acre-ft
- Inflow volume
- 1.955 acre-ft
- Storage peak time
- 79.15 min
- Inflow ends
- 87 min
- Orifice discharge
- 4.76 cfs
- Weir discharge
- 2.19 cfs
- Head above orifice center
- 4.7 ft
- Head above weir crest
- 0.3 ft
- Release rate reserve
- -0.55 cfs
Worked calculation
Compare the required volume with the available capacity before changing the outlet. The rating at full stage is a separate release check.
Vreq = 60[Qin(tᵈ + t꜀/4) − Qout(tᵈ/2 + 3t꜀/4)] · Full orifice Qor = CᵈA√(2gh) · Qw = CʷLh³ᐟ².
The hydrograph assumes tᵈ ≥ t꜀, a 1.5 t꜀ recession and a linear release rising limb. Storage is set to zero when the allowable rate already meets the inflow peak. Test multiple IDF durations to find the controlling one. The steady-flow rating uses the EPA SWMM equivalent weir for a partly wetted side orifice and centerline head for a full opening. Downstream submergence and dynamic routing require a separate analysis.
More worked examples
Open the main calculatorRetail detention pond for a longer storm
Inputs
- Post-development inflow
- 22 cfs
- Allowable release
- 6.4 cfs
- Storm duration tᵈ
- 60 min
- Time of concentration t꜀
- 18 min
- Bottom length
- 106 ft
- Bottom width
- 62 ft
- Water depth above bottom
- 5.5 ft
- Side slope z (H:V)
- 3
- Orifice diameter
- 9 in
- Orifice coefficient Cᵈ
- 0.62
- Orifice center above bottom
- 0.8 ft
- Weir crest length
- 4 ft
- Weir coefficient Cʷ
- 3.33 ft½/s
- Weir crest above bottom
- 5.2 ft
Results
- Storage req.
- 1.571 acre-ft
- Basin volume
- 1.226 acre-ft
- Outlet rating
- 6.95 cfs
- Storage reserve
- -0.345 acre-ft
- Inflow volume
- 1.955 acre-ft
- Storage peak time
- 79.15 min
- Inflow ends
- 87 min
- Orifice discharge
- 4.76 cfs
- Weir discharge
- 2.19 cfs
- Head above orifice center
- 4.7 ft
- Head above weir crest
- 0.3 ft
- Release rate reserve
- -0.55 cfs
Basin storage shortfall
Checks use the selected storm duration and report the outlet rating at the entered water depth.
Vreq = 60[Qin(tᵈ + t꜀/4) − Qout(tᵈ/2 + 3t꜀/4)] · Full orifice Qor = CᵈA√(2gh) · Qw = CʷLh³ᐟ².
Screening worksheet · Verify design using project criteria and site data.