Worked example · Conveyance

Aged storm sewer with custom roughness

Visual inspection indicates a rougher interior than standard new concrete. Use a custom Manning value for the comparison.

Inputs

Pipe section
4–180 in
0–100 %
0–30 %

The full reference uses the same slope and roughness as the partial section.

Roughness and velocity
0.008–0.1
0.1–15 ft/s

Typical screening targets are 2–3 ft/s (about 0.6–0.9 m/s). Use your agency’s criterion.

Circular pipe section

Live results
Circular pipe section Velocity meets the target. Self-cleansing screen at the entered depth and grade. PARTIAL FLOW 15.28 cfs FULL FLOW 17.91 cfs VELOCITY 3.39 ft/s Q / Q FULL 85.3 % Depth d1.95 ftPipe D33 inInvert 0Velocity target2× target

Velocity meets the target

Self-cleansing screen at the entered depth and grade.

Calculation results

Partial flow
15.28 cfs
Full flow
17.91 cfs
Velocity
3.39 ft/s
Q / Q full
85.3 %
Full-flow velocity
3.02 ft/s
Velocity ratio
112.3 %
Flow depth
1.95 ft
Central angle θ
4.008 rad
Wetted area
4.51 ft²
Hydraulic radius
0.818 ft
Wetted perimeter
5.51 ft
Velocity reserve
1.09 ft/s

Worked calculation

Change Manning n while holding depth and slope fixed. Both velocities change while the flow ratio stays fixed.

θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.

Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.