Inputs
Circular pipe section
Live resultsVelocity meets the target
Self-cleansing screen at the entered depth and grade.
Calculation results
- Partial flow
- 15.28 cfs
- Full flow
- 17.91 cfs
- Velocity
- 3.39 ft/s
- Q / Q full
- 85.3 %
- Full-flow velocity
- 3.02 ft/s
- Velocity ratio
- 112.3 %
- Flow depth
- 1.95 ft
- Central angle θ
- 4.008 rad
- Wetted area
- 4.51 ft²
- Hydraulic radius
- 0.818 ft
- Wetted perimeter
- 5.51 ft
- Velocity reserve
- 1.09 ft/s
Worked calculation
Change Manning n while holding depth and slope fixed. Both velocities change while the flow ratio stays fixed.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.
Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.
More worked examples
Open the main calculatorAged storm sewer with custom roughness
Inputs
- Inside diameter D
- 33 in
- Depth ratio d/D
- 71 %
- Longitudinal grade
- 0.22 %
- Pipe material
- Custom Manning n
- Manning n
- 0.018
- Minimum velocity
- 2.3 ft/s
Results
- Partial flow
- 15.28 cfs
- Full flow
- 17.91 cfs
- Velocity
- 3.39 ft/s
- Q / Q full
- 85.3 %
- Full-flow velocity
- 3.02 ft/s
- Velocity ratio
- 112.3 %
- Flow depth
- 1.95 ft
- Central angle θ
- 4.008 rad
- Wetted area
- 4.51 ft²
- Hydraulic radius
- 0.818 ft
- Wetted perimeter
- 5.51 ft
- Velocity reserve
- 1.09 ft/s
Velocity meets the target
Self-cleansing screen at the entered depth and grade.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.