Worked example · Conveyance

Corrugated storm pipe near the crown

A corrugated-metal storm drain is close to full, at 93% of its inside diameter.

Inputs

Pipe section
4–180 in
0–100 %
0–30 %

The full reference uses the same slope and roughness as the partial section.

Roughness and velocity
0.1–15 ft/s

Typical screening targets are 2–3 ft/s (about 0.6–0.9 m/s). Use your agency’s criterion.

Circular pipe section

Live results
Circular pipe section Velocity meets the target. Self-cleansing screen at the entered depth and grade. PARTIAL FLOW 65.87 cfs FULL FLOW 61.26 cfs VELOCITY 5.41 ft/s Q / Q FULL 107.5 % Depth d3.72 ftPipe D48 inInvert 0Velocity target2× target

Velocity meets the target

Self-cleansing screen at the entered depth and grade.

Calculation results

Partial flow
65.87 cfs
Full flow
61.26 cfs
Velocity
5.41 ft/s
Q / Q full
107.5 %
Full-flow velocity
4.88 ft/s
Velocity ratio
110.9 %
Flow depth
3.72 ft
Central angle θ
5.212 rad
Wetted area
12.18 ft²
Hydraulic radius
1.168 ft
Wetted perimeter
10.42 ft
Velocity reserve
2.41 ft/s

Worked calculation

The part-full flow can exceed Q full because the wetted perimeter falls faster than area near the crown. Set depth to 100% to compare.

θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.

Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.