Worked example · Conveyance
Corrugated storm pipe near the crown
A corrugated-metal storm drain is close to full, at 93% of its inside diameter.
Inputs
Circular pipe section
Live resultsVelocity meets the target
Self-cleansing screen at the entered depth and grade.
Calculation results
- Partial flow
- 65.87 cfs
- Full flow
- 61.26 cfs
- Velocity
- 5.41 ft/s
- Q / Q full
- 107.5 %
- Full-flow velocity
- 4.88 ft/s
- Velocity ratio
- 110.9 %
- Flow depth
- 3.72 ft
- Central angle θ
- 5.212 rad
- Wetted area
- 12.18 ft²
- Hydraulic radius
- 1.168 ft
- Wetted perimeter
- 10.42 ft
- Velocity reserve
- 2.41 ft/s
Worked calculation
The part-full flow can exceed Q full because the wetted perimeter falls faster than area near the crown. Set depth to 100% to compare.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.
Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.
More worked examples
Open the main calculatorCorrugated storm pipe near the crown
Inputs
- Inside diameter D
- 48 in
- Depth ratio d/D
- 93 %
- Longitudinal grade
- 0.62 %
- Pipe material
- CMP · n 0.024
- Minimum velocity
- 3 ft/s
Results
- Partial flow
- 65.87 cfs
- Full flow
- 61.26 cfs
- Velocity
- 5.41 ft/s
- Q / Q full
- 107.5 %
- Full-flow velocity
- 4.88 ft/s
- Velocity ratio
- 110.9 %
- Flow depth
- 3.72 ft
- Central angle θ
- 5.212 rad
- Wetted area
- 12.18 ft²
- Hydraulic radius
- 1.168 ft
- Wetted perimeter
- 10.42 ft
- Velocity reserve
- 2.41 ft/s
Velocity meets the target
Self-cleansing screen at the entered depth and grade.
θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.