Worked example · Controls & protection
Apron screening beyond HEC-14 tailwater range
A deeply submerged culvert discharges into a downstream channel with tailwater higher than the outlet diameter.
Inputs
Riprap apron plan
Live resultsAvailable stone meets D₅₀
Higher tailwater (TW ≥ 0.5Dₒ). Example class dimensions use the next qualifying size.
Tailwater exceeds the Eq. 10.4 range. The reported size is a cap-based screen. See HEC-14 §10.3.
Calculation results
- Required D₅₀
- 1.27 in
- Apron length
- 12 ft
- Flared width
- 17 ft
- Placed mass
- 11.83 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 9 ft
- Placed volume
- 227.5 ft³
- Available stone reserve
- 4.73 in
- Tailwater used
- 3 ft
- Effective diameter
- 3 ft
- Actual TW / Dₒ
- 1.333
Worked calculation
The capped calculation is a screening figure. Use the HEC-14 downstream velocity approach to evaluate this condition for design.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.
More worked examples
Open the main calculatorApron screening beyond HEC-14 tailwater range
Inputs
- Outlet flow per barrel
- 24 cfs
- Outlet inside diameter
- 36 in
- Tailwater depth
- 4 ft
- Outlet flow regime
- Subcritical / unknown
- Available stone D₅₀
- 6 in
- Stone specific gravity
- 2.65
- Placed bulk density
- 104 lb/ft³
Results
- Required D₅₀
- 1.27 in
- Apron length
- 12 ft
- Flared width
- 17 ft
- Placed mass
- 11.83 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 9 ft
- Placed volume
- 227.5 ft³
- Available stone reserve
- 4.73 in
- Tailwater used
- 3 ft
- Effective diameter
- 3 ft
- Actual TW / Dₒ
- 1.333
Available stone meets D₅₀
Higher tailwater (TW ≥ 0.5Dₒ). Example class dimensions use the next qualifying size.
Tailwater exceeds the Eq. 10.4 range. The reported size is a cap-based screen. See HEC-14 §10.3.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
Screening worksheet · Verify design using project criteria and site data.