Worked example · Controls & protection
Riprap apron with unknown tailwater
A small site outfall has no reliable downstream water-level record. Enter zero to apply the HEC-14 lower bound for stone sizing.
Inputs
Riprap apron plan
Live resultsAvailable stone meets D₅₀
Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.
Stone sizing uses the minimum tailwater of 0.4 effective diameters.
Calculation results
- Required D₅₀
- 1.91 in
- Apron length
- 8 ft
- Flared width
- 11.33 ft
- Placed mass
- 5.16 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 6 ft
- Placed volume
- 101.11 ft³
- Available stone reserve
- 3.09 in
- Tailwater used
- 0.8 ft
- Effective diameter
- 2 ft
- Actual TW / Dₒ
- 0
Worked calculation
Raise tailwater past 0.4D to see the required size fall. The USDA low-tailwater classification changes at 0.5D.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.
More worked examples
Open the main calculatorRiprap apron with unknown tailwater
Inputs
- Outlet flow per barrel
- 8.1 cfs
- Outlet inside diameter
- 24 in
- Tailwater depth
- 0 ft
- Outlet flow regime
- Subcritical / unknown
- Available stone D₅₀
- 5 in
- Stone specific gravity
- 2.65
- Placed bulk density
- 102 lb/ft³
Results
- Required D₅₀
- 1.91 in
- Apron length
- 8 ft
- Flared width
- 11.33 ft
- Placed mass
- 5.16 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 6 ft
- Placed volume
- 101.11 ft³
- Available stone reserve
- 3.09 in
- Tailwater used
- 0.8 ft
- Effective diameter
- 2 ft
- Actual TW / Dₒ
- 0
Available stone meets D₅₀
Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.
Stone sizing uses the minimum tailwater of 0.4 effective diameters.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.