Worked example · Controls & protection
Riprap apron under higher tailwater
A downstream ditch normally covers more than half the culvert diameter during the evaluated storm.
Inputs
Riprap apron plan
Live resultsAvailable stone meets D₅₀
Higher tailwater (TW ≥ 0.5Dₒ). Example class dimensions use the next qualifying size.
Calculation results
- Required D₅₀
- 2.07 in
- Apron length
- 10.67 ft
- Flared width
- 15.11 ft
- Placed mass
- 9.71 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 8 ft
- Placed volume
- 179.75 ft³
- Available stone reserve
- 3.93 in
- Tailwater used
- 1.8 ft
- Effective diameter
- 2.67 ft
- Actual TW / Dₒ
- 0.675
Worked calculation
The available rock can be screened against the continuous D₅₀ result while the apron dimensions use the next table class.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.
More worked examples
Open the main calculatorRiprap apron under higher tailwater
Inputs
- Outlet flow per barrel
- 21 cfs
- Outlet inside diameter
- 32 in
- Tailwater depth
- 1.8 ft
- Outlet flow regime
- Subcritical / unknown
- Available stone D₅₀
- 6 in
- Stone specific gravity
- 2.65
- Placed bulk density
- 108 lb/ft³
Results
- Required D₅₀
- 2.07 in
- Apron length
- 10.67 ft
- Flared width
- 15.11 ft
- Placed mass
- 9.71 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 8 ft
- Placed volume
- 179.75 ft³
- Available stone reserve
- 3.93 in
- Tailwater used
- 1.8 ft
- Effective diameter
- 2.67 ft
- Actual TW / Dₒ
- 0.675
Available stone meets D₅₀
Higher tailwater (TW ≥ 0.5Dₒ). Example class dimensions use the next qualifying size.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
Screening worksheet · Verify design using project criteria and site data.