Worked example · Controls & protection
Stockpiled stone smaller than the requirement
A roadside maintenance yard has 6 in median stone available for a concentrated outfall.
Inputs
Riprap apron plan
Live resultsAvailable stone is too small
Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.
Calculation results
- Required D₅₀
- 6.81 in
- Apron length
- 12.5 ft
- Flared width
- 15.83 ft
- Placed mass
- 15.46 US ton
- Example class D₅₀
- 10 in
- Apron thickness
- 24 in
- Upstream apron width
- 7.5 ft
- Placed volume
- 291.67 ft³
- Available stone reserve
- -0.81 in
- Tailwater used
- 1 ft
- Effective diameter
- 2.5 ft
- Actual TW / Dₒ
- 0.4
Worked calculation
Compare the stockpile against the continuous hydraulic requirement. A larger qualifying class may also change apron length and thickness.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.
More worked examples
Open the main calculatorStockpiled stone smaller than the requirement
Inputs
- Outlet flow per barrel
- 31 cfs
- Outlet inside diameter
- 30 in
- Tailwater depth
- 1 ft
- Outlet flow regime
- Subcritical / unknown
- Available stone D₅₀
- 6 in
- Stone specific gravity
- 2.65
- Placed bulk density
- 106 lb/ft³
Results
- Required D₅₀
- 6.81 in
- Apron length
- 12.5 ft
- Flared width
- 15.83 ft
- Placed mass
- 15.46 US ton
- Example class D₅₀
- 10 in
- Apron thickness
- 24 in
- Upstream apron width
- 7.5 ft
- Placed volume
- 291.67 ft³
- Available stone reserve
- -0.81 in
- Tailwater used
- 1 ft
- Effective diameter
- 2.5 ft
- Actual TW / Dₒ
- 0.4
Available stone is too small
Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
Screening worksheet · Verify design using project criteria and site data.