Worked example · Controls & protection
Supercritical outlet with adjusted diameter
A steep barrel exits at an estimated 11 in normal flow depth inside a 36 in pipe.
Inputs
Riprap apron plan
Live resultsAvailable stone meets D₅₀
Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.
Stone sizing uses the minimum tailwater of 0.4 effective diameters.
Calculation results
- Required D₅₀
- 3.97 in
- Apron length
- 12 ft
- Flared width
- 17 ft
- Placed mass
- 12.85 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 9 ft
- Placed volume
- 227.5 ft³
- Available stone reserve
- 2.03 in
- Tailwater used
- 0.78 ft
- Effective diameter
- 1.96 ft
- Actual TW / Dₒ
- 0.217
Worked calculation
The 23.5 in effective diameter changes the stone size, while the apron length and initial width still reference the physical outlet.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.
More worked examples
Open the main calculatorSupercritical outlet with adjusted diameter
Inputs
- Outlet flow per barrel
- 13.5 cfs
- Outlet inside diameter
- 36 in
- Tailwater depth
- 0.65 ft
- Outlet flow regime
- Supercritical
- Supercritical normal depth
- 11 in
- Available stone D₅₀
- 6 in
- Stone specific gravity
- 2.65
- Placed bulk density
- 113 lb/ft³
Results
- Required D₅₀
- 3.97 in
- Apron length
- 12 ft
- Flared width
- 17 ft
- Placed mass
- 12.85 US ton
- Example class D₅₀
- 5 in
- Apron thickness
- 17.5 in
- Upstream apron width
- 9 ft
- Placed volume
- 227.5 ft³
- Available stone reserve
- 2.03 in
- Tailwater used
- 0.78 ft
- Effective diameter
- 1.96 ft
- Actual TW / Dₒ
- 0.217
Available stone meets D₅₀
Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.
Stone sizing uses the minimum tailwater of 0.4 effective diameters.
D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.
Screening worksheet · Verify design using project criteria and site data.