Worked example · Controls & protection

Riprap apron with unknown tailwater

A small site outfall has no reliable downstream water-level record. Enter zero to apply the HEC-14 lower bound for stone sizing.

Inputs

Culvert outfall
0–1,500 cfs
6–144 in
0–20 ft

For unknown tailwater enter zero. The HEC-14 minimum is applied automatically.

Stone and placement
0–60 in
2–4
40–200 lb/ft³

Use in-place bulk density, including voids, for material tonnage.

Riprap apron plan

Live results
Riprap apron plan Available stone meets D₅₀. Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size. REQUIRED D₅₀ 1.91 in APRON LENGTH 8 ft FLARED WIDTH 11.33 ft PLACED MASS 5.16 US ton Circular outletLow tailwaterW₂Lₐ · 8 ft 0Required D₅₀2× required

Available stone meets D₅₀

Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.

Stone sizing uses the minimum tailwater of 0.4 effective diameters.

Calculation results

Required D₅₀
1.91 in
Apron length
8 ft
Flared width
11.33 ft
Placed mass
5.16 US ton
Example class D₅₀
5 in
Apron thickness
17.5 in
Upstream apron width
6 ft
Placed volume
101.11 ft³
Available stone reserve
3.09 in
Tailwater used
0.8 ft
Effective diameter
2 ft
Actual TW / Dₒ
0

Worked calculation

Raise tailwater past 0.4D to see the required size fall. The USDA low-tailwater classification changes at 0.5D.

D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.

HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.

Open the main calculator

Share this calculation