Conveyance

Partially Full Storm Sewer Calculator

Compare part-full and full circular pipe flow, and check the velocity against your self-cleansing target.

Inputs

Pipe section
4–180 in
0–100 %
0–30 %

The full reference uses the same slope and roughness as the partial section.

Roughness and velocity
0.1–15 ft/s

Typical screening targets are 2–3 ft/s (about 0.6–0.9 m/s). Use your agency’s criterion.

Circular pipe section

Live results
Circular pipe section Velocity meets the target. Self-cleansing screen at the entered depth and grade. PARTIAL FLOW 19.48 cfs FULL FLOW 29 cfs VELOCITY 6.34 ft/s Q / Q FULL 67.2 % Depth d1.5 ftPipe D30 inInvert 0Velocity target2× target

Velocity meets the target

Self-cleansing screen at the entered depth and grade.

Calculation results

Partial flow
19.48 cfs
Full flow
29 cfs
Velocity
6.34 ft/s
Q / Q full
67.2 %
Full-flow velocity
5.91 ft/s
Velocity ratio
107.2 %
Flow depth
1.5 ft
Central angle θ
3.544 rad
Wetted area
3.08 ft²
Hydraulic radius
0.694 ft
Wetted perimeter
4.43 ft
Velocity reserve
3.84 ft/s

Method and assumptions

θ = 2 acos(1 − 2d/D) · A = D²(θ − sin θ)/8 · P = Dθ/2 · Q = K A R²ᐟ³ S¹ᐟ²/n.

Assumes uniform gravity flow with fixed Manning n and no backwater. At a zero slope the ratios compare section conveyance, while both discharges and velocities are zero. At high part-full depths Q can exceed its full-section reference because hydraulic radius is larger.

Share this calculation

This link opens the worksheet with your current inputs and units.