Worked example · Fence layout
12-Inch Fence Post Holes with a 6-Inch Gravel Base
A straight 48 ft fence needs seven 4×4 posts at 8 ft spacing. Model 12 in. diameter holes and 6 in. of gravel under each concrete collar.
Example inputs
Worked result
Updates as you type- Posts including both ends
- 7
- Modeled concrete embedment
- 61 in
- 60 lb bags per post
- 9
Fence grade and post section
SchematicProject inputs
- Horizontal fence length
- 48 ft
- Exposed fence height
- 4 ft
- Fence style
- Picket
- Maximum bay along rail
- 8 ft
- Signed change in ground height
- 0 ft
- Slope layout
- Rack to the slope
- Post stock
- 4 × 4 nominal
- Hole diameter
- 12 in
- Minimum concrete embedment
- 30 in
- Gravel below concrete
- 6 in
- Bag product weight
- 60 lb bag
- Concrete waste allowance
- 10%
- Allowable-stress net wind pressure
- 12 psf
- Lateral bearing increase per depth
- 150 psf/ft
Calculation details
- Posts including both ends
- 7
- Modeled concrete embedment
- 61 in
- 60 lb bags per post
- 9
- Equal fence bays
- 6
- Horizontal post spacing
- 8 ft
- Rail-line length per bay
- 8 ft
- Ground change per racked bay
- 0 ft
- Rails in the material estimate
- 12
- Wind force per interior post
- 384 lb
- Wind-only soil embedment screen
- 60.8 in
- Total hole depth with gravel
- 67 in
- Longest estimated post stock
- 9.08 ft
- Concrete per post before waste
- 3.56 ft³
- Total bags, rounded per hole
- 63
- Total gravel base
- 2.749 ft³
Checks and references
- Reference
Wind and lateral soil assumptions
Use a site-specific allowable-stress net wind pressure on the gross projected fence area and a locally verified lateral soil value. The estimate uses the unconstrained IBC 1807.3.2.1 screen.
- Reference
Post, panels and gates
Check post bending, hardware, panel span, corner and gate loads, local fence rules and frost requirements with the authority having jurisdiction.
Worked calculation
The steps use US customary units for the reference formulas.
Space the fence posts
Divide the 48 ft racked rail line by the entered bay limit and round up. 6 bays take 7 posts at 8 ft horizontally.
Estimate the wind embedment
12 psf × 4 ft × 8 ft = 384 lb per interior post. The unconstrained embedded-post equation gives 60.83 in for the entered soil gradient and lateral load at half height.
Order concrete and gravel
Use 61 in embedment and 6 in gravel. Subtract the embedded post volume from the cylinder, apply waste, and round per hole to 9 bags. Gravel is 2.75 ft³ total.
Set panel elevations
Slope the rails to follow the grade. Each bay changes elevation by 0 ft with a 8 ft rail line before end allowances.
Enter valid values to see the steps for this layout.
Frequently asked questions
How much gravel is in seven 12 in. holes with 6 in. bases?
At the full hole diameter, seven half-foot gravel cylinders total about 2.75 ft³ before any compaction allowance.
Why is the 4×4 post subtracted from concrete volume?
The embedded portion occupies part of the hole. Concrete forms the surrounding collar, while the gravel calculation uses the full area below it.