Worked example · Fence layout
160 ft Three-Rail Ranch Fence Post Count
A 4 ft ranch fence has three rails per bay and a 10 ft maximum spacing. Use a locally determined net wind pressure on the gross projected face.
Example inputs
Worked result
Updates as you type- Posts including both ends
- 17
- Modeled concrete embedment
- 50 in
- 80 lb bags per post
- 10
Fence grade and post section
SchematicProject inputs
- Horizontal fence length
- 160 ft
- Exposed fence height
- 4 ft
- Fence style
- Ranch rail
- Maximum bay along rail
- 10 ft
- Signed change in ground height
- 0 ft
- Slope layout
- Rack to the slope
- Post stock
- 6 × 6 nominal
- Hole diameter
- 16 in
- Minimum concrete embedment
- 36 in
- Gravel below concrete
- 6 in
- Bag product weight
- 80 lb bag
- Concrete waste allowance
- 10%
- Allowable-stress net wind pressure
- 8 psf
- Lateral bearing increase per depth
- 150 psf/ft
Calculation details
- Posts including both ends
- 17
- Modeled concrete embedment
- 50 in
- 80 lb bags per post
- 10
- Equal fence bays
- 16
- Horizontal post spacing
- 10 ft
- Rail-line length per bay
- 10 ft
- Ground change per racked bay
- 0 ft
- Rails in the material estimate
- 48
- Wind force per interior post
- 320 lb
- Wind-only soil embedment screen
- 49.7 in
- Total hole depth with gravel
- 56 in
- Longest estimated post stock
- 8.17 ft
- Concrete per post before waste
- 4.942 ft³
- Total bags, rounded per hole
- 170
- Total gravel base
- 11.868 ft³
Checks and references
- Reference
Wind and lateral soil assumptions
Use a site-specific allowable-stress net wind pressure on the gross projected fence area and a locally verified lateral soil value. The estimate uses the unconstrained IBC 1807.3.2.1 screen.
- Reference
Post, panels and gates
Check post bending, hardware, panel span, corner and gate loads, local fence rules and frost requirements with the authority having jurisdiction.
Worked calculation
The steps use US customary units for the reference formulas.
Space the fence posts
Divide the 160 ft racked rail line by the entered bay limit and round up. 16 bays take 17 posts at 10 ft horizontally.
Estimate the wind embedment
8 psf × 4 ft × 10 ft = 320 lb per interior post. The unconstrained embedded-post equation gives 49.69 in for the entered soil gradient and lateral load at half height.
Order concrete and gravel
Use 50 in embedment and 6 in gravel. Subtract the embedded post volume from the cylinder, apply waste, and round per hole to 10 bags. Gravel is 11.87 ft³ total.
Set panel elevations
Slope the rails to follow the grade. Each bay changes elevation by 0 ft with a 10 ft rail line before end allowances.
Enter valid values to see the steps for this layout.
Frequently asked questions
How many rails are in sixteen bays of a three-rail ranch fence?
Three rails times sixteen bays gives forty-eight rail lengths before trimming or overlap.
Does the ranch rail preset determine the actual wind pressure to enter?
The preset sets the rail count. Use a site-specific net pressure for the fence’s actual porosity and exposure.