Worked example · Fence layout
Racked 60 ft Picket Fence with 9 ft of Fall
A 4 ft picket fence descends nine feet over a horizontal 60 ft run. Limit the rails to six feet along the slope and account for the longer sloped line.
Example inputs
Worked result
Updates as you type- Posts including both ends
- 12
- Modeled concrete embedment
- 48 in
- 80 lb bags per post
- 6
Fence grade and post section
SchematicProject inputs
- Horizontal fence length
- 60 ft
- Exposed fence height
- 4 ft
- Fence style
- Picket
- Maximum bay along rail
- 6 ft
- Signed change in ground height
- -9 ft
- Slope layout
- Rack to the slope
- Post stock
- 4 × 4 nominal
- Hole diameter
- 12 in
- Minimum concrete embedment
- 30 in
- Gravel below concrete
- 6 in
- Bag product weight
- 80 lb bag
- Concrete waste allowance
- 10%
- Allowable-stress net wind pressure
- 10 psf
- Lateral bearing increase per depth
- 150 psf/ft
Calculation details
- Posts including both ends
- 12
- Modeled concrete embedment
- 48 in
- 80 lb bags per post
- 6
- Equal fence bays
- 11
- Horizontal post spacing
- 5.45 ft
- Rail-line length per bay
- 5.52 ft
- Ground change per racked bay
- 0.82 ft
- Rails in the material estimate
- 22
- Wind force per interior post
- 218 lb
- Wind-only soil embedment screen
- 47.7 in
- Total hole depth with gravel
- 54 in
- Longest estimated post stock
- 8 ft
- Concrete per post before waste
- 2.801 ft³
- Total bags, rounded per hole
- 72
- Total gravel base
- 4.712 ft³
Checks and references
- Reference
Wind and lateral soil assumptions
Use a site-specific allowable-stress net wind pressure on the gross projected fence area and a locally verified lateral soil value. The estimate uses the unconstrained IBC 1807.3.2.1 screen.
- Reference
Post, panels and gates
Check post bending, hardware, panel span, corner and gate loads, local fence rules and frost requirements with the authority having jurisdiction.
Worked calculation
The steps use US customary units for the reference formulas.
Space the fence posts
Divide the 60.67 ft racked rail line by the entered bay limit and round up. 11 bays take 12 posts at 5.45 ft horizontally.
Estimate the wind embedment
10 psf × 4 ft × 5.45 ft = 218.18 lb per interior post. The unconstrained embedded-post equation gives 47.71 in for the entered soil gradient and lateral load at half height.
Order concrete and gravel
Use 48 in embedment and 6 in gravel. Subtract the embedded post volume from the cylinder, apply waste, and round per hole to 6 bags. Gravel is 4.71 ft³ total.
Set panel elevations
Slope the rails to follow the grade. Each bay changes elevation by 0.82 ft with a 5.52 ft rail line before end allowances.
Enter valid values to see the steps for this layout.
Frequently asked questions
Why does the 60 ft racked fence use eleven bays when six divides sixty?
Six feet is the allowed rail length along the slope. The full line is about 60.67 ft, requiring another bay.
What does a negative grade entry do to the racked fence drawing?
A negative value slopes the ground down from left to right. Post spacing uses the same sloped line length for an equal rise or fall.