Worked example · Fence layout

Racked 60 ft Picket Fence with 9 ft of Fall

A 4 ft picket fence descends nine feet over a horizontal 60 ft run. Limit the rails to six feet along the slope and account for the longer sloped line.

Example inputs

Fence run
ft
ft
ft
ft
Post and hole materials
in
in
in
%
Wind and lateral soil
psf
Pressure on the gross fence face.
psf/ft
Use the value accepted for the site soil.
See results

Worked result

Updates as you type
Posts including both ends
12
Modeled concrete embedment
48 in
80 lb bags per post
6

Fence grade and post section

Schematic
Fence grade and post section Racked picket fence7 of 11 bays shown · 5.45 ft OCPost section48 in embedment6 in gravel

Calculation details

Posts including both ends
12
Modeled concrete embedment
48 in
80 lb bags per post
6
Equal fence bays
11
Horizontal post spacing
5.45 ft
Rail-line length per bay
5.52 ft
Ground change per racked bay
0.82 ft
Rails in the material estimate
22
Wind force per interior post
218 lb
Wind-only soil embedment screen
47.7 in
Total hole depth with gravel
54 in
Longest estimated post stock
8 ft
Concrete per post before waste
2.801 ft³
Total bags, rounded per hole
72
Total gravel base
4.712 ft³

Checks and references

  • Reference
    Wind and lateral soil assumptions

    Use a site-specific allowable-stress net wind pressure on the gross projected fence area and a locally verified lateral soil value. The estimate uses the unconstrained IBC 1807.3.2.1 screen.

  • Reference
    Post, panels and gates

    Check post bending, hardware, panel span, corner and gate loads, local fence rules and frost requirements with the authority having jurisdiction.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Space the fence posts

    Divide the 60.67 ft racked rail line by the entered bay limit and round up. 11 bays take 12 posts at 5.45 ft horizontally.

  2. Estimate the wind embedment

    10 psf × 4 ft × 5.45 ft = 218.18 lb per interior post. The unconstrained embedded-post equation gives 47.71 in for the entered soil gradient and lateral load at half height.

  3. Order concrete and gravel

    Use 48 in embedment and 6 in gravel. Subtract the embedded post volume from the cylinder, apply waste, and round per hole to 6 bags. Gravel is 4.71 ft³ total.

  4. Set panel elevations

    Slope the rails to follow the grade. Each bay changes elevation by 0.82 ft with a 5.52 ft rail line before end allowances.

Frequently asked questions

Why does the 60 ft racked fence use eleven bays when six divides sixty?

Six feet is the allowed rail length along the slope. The full line is about 60.67 ft, requiring another bay.

What does a negative grade entry do to the racked fence drawing?

A negative value slopes the ground down from left to right. Post spacing uses the same sloped line length for an equal rise or fall.

Other calculators