Gas bleed & SCCM conversion / Worked example

Nitrogen Purge Through a Precision Nozzle

Nitrogen enters through a 52 μm precision orifice from 1 atm into a low-pressure chamber.

Readout ↓

Inputs

Flow basis and process chamber
°C
L/s
Orifice and upstream gas
Pa
Pa
°C
mm
Enter a value above 0 and at most 1.

Live readout

Choked flow
Standard flow19.42SCCMMass flow0.4046mg/sChamber load0.0352Pa·m³/sProcess P0.607PaP₁Gas supplyQOrifice0.052 mmP₂Process0.607 PaProcess pressure · Pa vs SCCM00.501101632Reference0 °C / 1 atmP₂ / P₁6.42e-6Critical ratio0.528
SCCM
19.42 SCCM
SLM
0.01942 SLM
Torr·L/s
0.246 Torr·L/s
mbar·L/s
0.328 mbar·L/s
Pa·m³/s
0.0328 Pa·m³/s
mol/s
1.444e-5 mol/s
mg/s
0.4046 mg/s
Throughput at chamber temperature
0.0352 Pa·m³/s
Predicted process pressure
0.607 Pa
Downstream / upstream ratio
6.415e-6
Critical pressure ratio
0.5283
Orifice upstream Kn
1.305e-3

    Reading this example

    The downstream pressure lies well below critical. The modeled flow is then set by upstream conditions and the throat.

    Model & assumptions

    Reference flow

    ṅ = PₛV̇ₛ/(RTₛ) · Q = ṅRT · ṁ = ṅM

    SCCM and SLM use the selected reference at 101,325 Pa. Throughput conversions in the unit table use the reference temperature. Process pressure uses the separately entered chamber temperature.

    Orifice choking

    r* = (2/(γ+1))^(γ/(γ−1)) · r = P₂/P₁

    Isentropic mass flow follows the subsonic pressure-ratio equation until the flow becomes sonic. Below the critical ratio the model holds mass flow at its choked value. Process pressure is chamber throughput divided by effective speed.