Gas bleed & SCCM conversion / Worked example
Nitrogen Purge Through a Precision Nozzle
Nitrogen enters through a 52 μm precision orifice from 1 atm into a low-pressure chamber.
Inputs
Live readout
Choked flow- SCCM
- 19.42 SCCM
- SLM
- 0.01942 SLM
- Torr·L/s
- 0.246 Torr·L/s
- mbar·L/s
- 0.328 mbar·L/s
- Pa·m³/s
- 0.0328 Pa·m³/s
- mol/s
- 1.444e-5 mol/s
- mg/s
- 0.4046 mg/s
- Throughput at chamber temperature
- 0.0352 Pa·m³/s
- Predicted process pressure
- 0.607 Pa
- Downstream / upstream ratio
- 6.415e-6
- Critical pressure ratio
- 0.5283
- Orifice upstream Kn
- 1.305e-3
Reading this example
The downstream pressure lies well below critical. The modeled flow is then set by upstream conditions and the throat.
Model & assumptions
Reference flow
ṅ = PₛV̇ₛ/(RTₛ) · Q = ṅRT · ṁ = ṅM
SCCM and SLM use the selected reference at 101,325 Pa. Throughput conversions in the unit table use the reference temperature. Process pressure uses the separately entered chamber temperature.
Orifice choking
r* = (2/(γ+1))^(γ/(γ−1)) · r = P₂/P₁