Vacuum Pipe Conductance & Effective Pumping Speed

Estimate molecular and viscous tube conductance, chamber pumping speed and the minimum pipe ID for 80% pump utilization.

Readout ↓

Inputs

Tube and pump
mm
m
Use zero for a thin aperture in molecular flow.
L/s
Pa
Gas and series restriction
°C
L/s
Enter 0 to omit a valve, baffle or other restriction.

Live readout

Molecular flow
Tube C250.7L/sChamber speed136.6L/sUtilization45.53%ID for 80%180.1mmChamberTubePumpID 100 mmChamber speed · L/s vs ID · mm01503000101202FlowMolecularPump speed300 L/s80% target240 L/s
Molecular conductance
250.7 L/s
Laminar conductance model
1.392 L/s
Molecular transmission
27.59%
Knudsen number Kn
18.99
Regime-adjusted tube conductance
250.7 L/s
Total series conductance
250.7 L/s
Effective chamber speed
136.6 L/s
Pump utilization
45.53%
Minimum inside diameter for 80%
180.1 mm

    Model & assumptions

    Tube throughput

    Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)

    The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.

    Chamber speed

    1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ

    Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.