WaterTreatLab

Granular filtration / Worked example

Low Rise Rate and Limited Bed Expansion

Explore the preliminary expansion warning at an 11 gpm/ft² wash rate on dual media without a measured bed height.

Inputs

Filter cell
ft²
ft
ft
Zero uses the estimate
gal/d
Water backwash
gpm/ft²
°F
min
d⁻¹
Air scour
scfm/ft²
min

Results

US customary
Backwash pump flow
1,650 gpm
Water per wash
13,200 gal
Bed expansion
7.3905 %
Daily UBRW
1.76 %
Filter bed fluidizationLive diagram
Filter bed fluidizationSettled and expanded bed profiles across the filter cell. Settled bed2.5 ftDuring wash2.6848 ftWater flow1,650 gpmExpansion7.3905 %Air volume1,980 scf
Settled and expanded bed profiles across the filter cell.
Review the operating point
  • Expansion is outside the 20–25% reference band. Verify the actual media bed and manufacturer wash targets.
Actual wash rise rate
11 gpm/ft² 26.892 m/h
Equivalent rise rate at 20 °C
11 gpm/ft² 26.892 m/h
Expanded depth
2.6848 ft
Daily washwater
13,200 gal/d
Air scour flow
495 scfm
Air volume per scour
1,980 scf
Water viscosity
1.0017 mPa·s

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. The water pump supplies 11 × 150 = 1,650 gpm. Eight minutes uses 13,200 gal.
  2. The illustrative fluidization model predicts about 7.39% expansion. Check actual bed rise and air-assisted performance.

More worked examples

Equations & conventions

Rise rate and washwater
Qwash = A × v, Vwash = Qwash × t

The result is gpm with area in ft² and rise rate in gpm/ft². UBRW is 100 × daily washwater / gross daily production for the same cell.

Temperature adjustment
μ = 0.02414 × 10^(247.8/(Tc + 133.15)), vT = v₂₀ × (μ₂₀/μT)^0.35

μ is an approximate water viscosity in mPa·s. Select whether the input is already at wash temperature or is the reference at 20 °C. The exponent is a planning assumption chosen to approximate seasonal behavior.

Measured bed expansion
Expansion = 100 × (expanded depth / settled depth − 1)

Enter the total operating bed depth during wash. The settled and expanded depths exclude support gravel.

Modeled bed expansion
ε = min(0.80, εref × (v₂₀/vref)^(1/3)); E = 100 × max(0, (1−ε₀)/(1−ε) − 1)

The porosity screen uses ε₀ = 0.40 and εref = 1 − (1 − ε₀)/1.225. The illustrative 20 °C reference rates are 15/17/19 gpm/ft² for sand/dual/anthracite. Use measured depth or a media-specific curve for plant decisions.

Air scour
Air volume = specific standard airflow × A × air time

Report gas volume at the same standard conditions as the entered rate. The 3–5 scfm/ft² Ten States reference applies to underdrain introduction.

Planning basis

The EPA water-wash expansion reference is commonly 20–25% and varies with media and air scour. Verify the bed with a rise measurement or media supplier curve and check trough clearance. The model assumes discrete water and air volumes.

Questions

Does the model capture bed expansion from the air stage?

The porosity estimate models the water wash. Enter field-measured rise if combined air and water affect the observed bed.