Measured Bed Rise on a Dual-Media Cell

Calculate expansion from measured operating depths and compare a 20 gpm/ft² backwash with its water volume.

Inputs

Filter cell
ft²
ft
ft
Zero uses the estimate
gal/d
Water backwash
gpm/ft²
°F
min
d⁻¹
Air scour
scfm/ft²
min

Results

US customary
Backwash pump flow
3,000 gpm
Water per wash
18,000 gal
Bed expansion
22.4 %
Daily UBRW
2.4 %
Filter bed fluidizationLive diagram
Filter bed fluidizationSettled and expanded bed profiles across the filter cell. Settled bed2.5 ftDuring wash3.06 ftWater flow3,000 gpmExpansion22.4 %Air volume2,400 scf
Settled and expanded bed profiles across the filter cell.
Actual wash rise rate
20 gpm/ft² 48.895 m/h
Equivalent rise rate at 20 °C
20 gpm/ft² 48.895 m/h
Expanded depth
3.06 ft
Daily washwater
18,000 gal/d
Air scour flow
600 scfm
Air volume per scour
2,400 scf
Water viscosity
1.0017 mPa·s

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. The increase from 2.50 to 3.06 ft is 0.56 ft. Divide by 2.50 and multiply by 100 for 22.4%.
  2. At 20 gpm/ft², 150 ft² requires 3,000 gpm. Six minutes uses 18,000 gal.

More worked examples

Equations & conventions

Rise rate and washwater
Qwash = A × v, Vwash = Qwash × t

The result is gpm with area in ft² and rise rate in gpm/ft². UBRW is 100 × daily washwater / gross daily production for the same cell.

Temperature adjustment
μ = 0.02414 × 10^(247.8/(Tc + 133.15)), vT = v₂₀ × (μ₂₀/μT)^0.35

μ is an approximate water viscosity in mPa·s. Select whether the input is already at wash temperature or is the reference at 20 °C. The exponent is a planning assumption chosen to approximate seasonal behavior.

Measured bed expansion
Expansion = 100 × (expanded depth / settled depth − 1)

Enter the total operating bed depth during wash. The settled and expanded depths exclude support gravel.

Modeled bed expansion
ε = min(0.80, εref × (v₂₀/vref)^(1/3)); E = 100 × max(0, (1−ε₀)/(1−ε) − 1)

The porosity screen uses ε₀ = 0.40 and εref = 1 − (1 − ε₀)/1.225. The illustrative 20 °C reference rates are 15/17/19 gpm/ft² for sand/dual/anthracite. Use measured depth or a media-specific curve for plant decisions.

Air scour
Air volume = specific standard airflow × A × air time

Report gas volume at the same standard conditions as the entered rate. The 3–5 scfm/ft² Ten States reference applies to underdrain introduction.

Planning basis

The EPA water-wash expansion reference is commonly 20–25% and varies with media and air scour. Verify the bed with a rise measurement or media supplier curve and check trough clearance. The model assumes discrete water and air volumes.

Questions

Do I enter measured rise or total expanded depth?

Enter the total expanded depth, 3.06 ft in this case. The calculation subtracts the settled depth.