WaterTreatLab

Disinfection / Worked example

Low UVT through a Wide Annular Gap

Compare exposure, water attenuation and estimated lamp count for 65% UVT and a 5 cm annular path.

Inputs

Reactor & water
gpm
gal
%
cm
cm
mJ/cm²
Lamp & quartz sleeve
mW/cm²
%
%
W
Biodosimetry (optional)
Both zero leaves RED blank
log/(mJ/cm²)

Results

US customary
Modeled UV dose
13.736 mJ/cm²
Mean exposure
4 s
Lamps for model target
15
Power for model target
6 kW
Annular UV intensityLive diagram
Annular UV intensityRadial intensity drops with distance from the quartz sleeve. Annular cross-sectionRelative intensityUVT 65 %10Sleeve5 cmNew lampDerated13.736 mJ/cm²
Radial intensity drops with distance from the quartz sleeve.
Review the operating point
  • The modeled dose is below the entered planning target. Select a validated reactor for the required operating envelope.
Biodosimetry RED
Requires test data
Derated annular mean
3.4339 mW/cm²
Absorption coefficient
0.43078 cm⁻¹
Sleeve × EOLL factor
63.75 %
Water-gap transmission
11.603 %
Installed lamp power
2 kW

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Water alone transmits 0.65⁵ ≈ 11.60% across a 5 cm path.
  2. With 4 s exposure and sleeve and lamp derating, five lamps give about 13.74 mJ/cm². The linear screening model estimates 15 lamps for 40 mJ/cm².

More worked examples

Equations & conventions

Water attenuation
α = −ln(UVT/100) / 1 cm, I(x)/I₀ = r₀/(r₀+x) × e^(−αx)

Use UVT at 254 nm over a 1 cm cell. The model assumes a cylindrical lamp, uniform water and a representative annular gap.

Annular mean and exposure
Ī = I₀ × [2r₀/(2r₀+L)] × [1−e^(−αL)]/(αL) × sleeve × EOLL × N

The absorption term tends to one at 100% UVT. Exposure is illuminated volume divided by flow, in seconds. Modeled dose is Ī × exposure in mJ/cm².

Planning lamp count
Nneeded = ceil(target / dose per lamp), kW = Nneeded × W / 1,000

The model holds hydraulic exposure and the independent contribution per lamp fixed. Use clean, new-lamp sleeve-interface intensity before the entered fouling and aging factors.

Reduction equivalent dose
RED = observed log inactivation / calibrated bench slope

Optional test inputs require a measured reactor challenge result and a log-linear bench curve through the origin over that response range. Use the validated envelope and validation factors for regulatory credit.

Planning basis

The optical estimate assumes uniform axial flow and independent lamp contributions. Short circuiting, lamp arrangement, sensor response and the dose distribution require manufacturer validation. EPA RED comes from biodosimetry.

Questions

Can I add ten lamps to this physical reactor based on the estimate?

Use the manufacturer’s reactor design and validation. The count assumes independent lamp contributions with fixed exposure and geometry.