WaterTreatLab

Disinfection / Worked example

88% UVT Annular Reactor Dose

Estimate optical dose, exposure and lamp count for a four-lamp reactor at 400 gpm and 88% UVT.

Inputs

Reactor & water
gpm
gal
%
cm
cm
mJ/cm²
Lamp & quartz sleeve
mW/cm²
%
%
W
Biodosimetry (optional)
Both zero leaves RED blank
log/(mJ/cm²)

Results

US customary
Modeled UV dose
37.316 mJ/cm²
Mean exposure
4.8 s
Lamps for model target
5
Power for model target
1.625 kW
Annular UV intensityLive diagram
Annular UV intensityRadial intensity drops with distance from the quartz sleeve. Annular cross-sectionRelative intensityUVT 88 %10Sleeve3 cmNew lampDerated37.316 mJ/cm²
Radial intensity drops with distance from the quartz sleeve.
Review the operating point
  • The modeled dose is below the entered planning target. Select a validated reactor for the required operating envelope.
Biodosimetry RED
Requires test data
Derated annular mean
7.7742 mW/cm²
Absorption coefficient
0.12783 cm⁻¹
Sleeve × EOLL factor
72 %
Water-gap transmission
68.147 %
Installed lamp power
1.3 kW

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. The 32 gal illuminated volume at 400 gpm gives 4.8 s mean exposure. With 88% UVT, α is 0.1278 cm⁻¹.
  2. The sleeve and EOLL factors multiply to 72%. The optical model gives about 37.32 mJ/cm² for four lamps and five lamps for the 40 mJ/cm² planning target.

More worked examples

Equations & conventions

Water attenuation
α = −ln(UVT/100) / 1 cm, I(x)/I₀ = r₀/(r₀+x) × e^(−αx)

Use UVT at 254 nm over a 1 cm cell. The model assumes a cylindrical lamp, uniform water and a representative annular gap.

Annular mean and exposure
Ī = I₀ × [2r₀/(2r₀+L)] × [1−e^(−αL)]/(αL) × sleeve × EOLL × N

The absorption term tends to one at 100% UVT. Exposure is illuminated volume divided by flow, in seconds. Modeled dose is Ī × exposure in mJ/cm².

Planning lamp count
Nneeded = ceil(target / dose per lamp), kW = Nneeded × W / 1,000

The model holds hydraulic exposure and the independent contribution per lamp fixed. Use clean, new-lamp sleeve-interface intensity before the entered fouling and aging factors.

Reduction equivalent dose
RED = observed log inactivation / calibrated bench slope

Optional test inputs require a measured reactor challenge result and a log-linear bench curve through the origin over that response range. Use the validated envelope and validation factors for regulatory credit.

Planning basis

The optical estimate assumes uniform axial flow and independent lamp contributions. Short circuiting, lamp arrangement, sensor response and the dose distribution require manufacturer validation. EPA RED comes from biodosimetry.

Questions

Why does this example leave biodosimetry RED blank?

It includes no measured challenge log inactivation or bench dose-response slope. The dose shown is the annular optical estimate.