Industrial machinery case

Process pump with two cold spares

A process pump operates alone with two dormant replacements. Each active pump has 14,000-hour MTBF under the assumed load.

Inputs

h
h
PassSystem survival meets single-component reference
R system
94.4013%
F system
5.59869%
Survival gain
51.964pp
MTTF multiple
3×

System topology and reliability

Reliability block diagram and system versus reference survivalCold standby2 dormantActiveSwitchSpareMission survival0%50%100%093301.9e42.8e4Time (h)SystemReferenceMission

The reference curve represents one component at the entered reference MTBF. Large topologies use representative blocks.

Download

Detailed results

System MTTF
42,000 h
Reference reliability
42.43728457 %
Required active blocks
1
Installed blocks
3

Under perfect changeover, system failure needs three active failures. The mean is three active lifetimes added together.

Formula trace

  1. Rᵢ(t) = exp(−t / MTBFᵢ)The single-block reference at 12,000 h is 0.42437285.
  2. Rsys = Pr(Poisson(t / MTBF) ≤ n−1)The topology gives Rsys = 0.94401306 and Fsys = 0.05598694.
  3. MTTFsys = ∫ Rsys(t) dt over t ≥ 0Mean system life is 42,000 h, or 3× reference MTBF.
  4. Survival gain = Rsys − RrefThe mission difference is 51.96402 percentage points.

Model assumptions

Blocks fail independently. Cold standby uses identical active failure rates, no dormant failures and perfect switching. Common-cause or imperfect switch failures require a separate model.

Method and sources

Related examples