Hyperscale infrastructure case

Server PSU 1-out-of-2 active redundancy

Two power supplies operate actively. Either can carry the load for a 12,000-hour mission with independent, constant hazards.

Inputs

h
h
h
Optional. Enter n values separated by commas.
PassSystem survival meets single-component reference
R system
99.6609%
F system
0.339137%
Survival gain
5.48441pp
MTTF multiple
1.5×

System topology and reliability

Reliability block diagram and system versus reference survivalActive parallel1 of 2 requiredB1B2Mission survival0%50%100%01.3e52.7e54e5Time (h)SystemReferenceMission

The reference curve represents one component at the entered reference MTBF. Large topologies use representative blocks.

Download

Detailed results

System MTTF
300,000 h
Reference reliability
94.17645336 %
Required active blocks
1
Installed blocks
2

The mean of the maximum of two identical exponential lives is 1.5 times the individual mean.

Formula trace

  1. Rᵢ(t) = exp(−t / MTBFᵢ)The single-block reference at 12,000 h is 0.94176453.
  2. Rsys = 1 − ∏ (1−Rᵢ(t))The topology gives Rsys = 0.99660863 and Fsys = 0.00339137.
  3. MTTFsys = ∫ Rsys(t) dt over t ≥ 0Mean system life is 300,000 h, or 1.5× reference MTBF.
  4. Survival gain = Rsys − RrefThe mission difference is 5.48441 percentage points.

Model assumptions

Blocks fail independently. Cold standby uses identical active failure rates, no dormant failures and perfect switching. Common-cause or imperfect switch failures require a separate model.