WeibullMTBFLab · Engineering calculation
Robot cell redundant safety monitor uptime
Two independently powered diagnostic monitors have different reliability fits. Evaluate the uptime of the monitored channel pair under an either-operates criterion.
System survival meets single-component reference
Inputs
- Block topology
- Active parallel
- Blocks n
- 2
- Reference component MTBF
- 40,000 h
- Mission age
- 10,000 h
- Individual component MTBFs
- 40,000, 55,000 h
Results
- R system
- 96.32262757 %
- F system
- 3.67737243 %
- Survival gain
- 18.44255 pp
- MTTF multiple
- 1.796053 ×
- System MTTF
- 71,842.11 h
- Reference reliability
- 77.88007831 %
- Required active blocks
- 1
- Installed blocks
- 2
Rᵢ(t) = exp(−t / MTBFᵢ)The single-block reference at 10,000 h is 0.77880078.Rsys = 1 − ∏ (1−Rᵢ(t))The topology gives Rsys = 0.96322628 and Fsys = 0.03677372.MTTFsys = ∫ Rsys(t) dt over t ≥ 0Mean system life is 71,842.11 h, or 1.796053× reference MTBF.Survival gain = Rsys − RrefThe mission difference is 18.44255 percentage points.
Blocks fail independently. Cold standby uses identical active failure rates, no dormant failures and perfect switching. Common-cause or imperfect switch failures require a separate model.