ASME IX · EN 1011-1
Fast GMAW travel below the WPS floor
A faster travel trial on a short solid-wire seam is compared against the same qualified heat-input window.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsNet heat window · 8.89 kJ/in to 17.78 kJ/in on an efficiency-adjusted basis.
Result details
| Net heat input | 6.264 kJ/in |
|---|---|
| Electrical arc energy | 7.83 kJ/in |
| Thermal efficiency | 80 % |
| Arc power | 3.65 kW |
| Energy used for check | 6.264 kJ/in |
| Solid steel wire feed (mass) | 4.69 lb/h |
| Estimated net wire deposition | 4.31 lb/h |
| Entered window minimum | 8.89 kJ/in |
| Entered window maximum | 17.78 kJ/in |
| Distance to nearest bound | -2.626 kJ/in |
Worked example
Starting inputs
- Arc voltage
- 21 V
- Arc current
- 174 A
- Travel speed
- 28 in/min
- Wire diameter
- 0.035433 in
- Wire feed speed
- 279.527559 in/min
- Minimum energy
- 8.89 kJ/in
- Maximum energy
- 17.78 kJ/in
Baseline results
- Net heat input
- 6.264 kJ/in
- Electrical arc energy
- 7.83 kJ/in
- Thermal efficiency
- 80 %
- Arc power
- 3.65 kW
With 3.65 kW at 28 in/min travel, electrical arc energy is 7.83 kJ/in. The 80 % process factor gives 6.264 kJ/in of net heat input.
Try it. Inspect the negative distance to the closest limit. This indicates how far the trial lies below the selected window.
Calculation method
Arc energy = 60P / v · Net heat input = η × 60P / v
Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.
Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.