WeldMetalLab

ASME IX · EN 1011-1

GMAW stiffener net heat window

A stiffener run uses solid wire and a procedure window expressed as net heat input. Confirm the baseline at the steady travel speed.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Arc parameters
V
A
mm/min
mm
m/min
WPS limits
kJ/mm
kJ/mm

Live weld sheet

Updated from inputs
Arc and weld poolNet heat input 0.883 kJ/mm. Electrical arc energy 1.103 kJ/mm. Thermal efficiency 80 %. Arc power 6.35 kW NET HEAT0.883kJ/mmARC ENERGY1.103kJ/mmTHERMAL EFF.80%ARC POWER6.35kW ARC AND WELD POOL Travel 345 mm/minArc 1.103 kJ/mmGMAW NET HEAT WINDOWPASS
Pass · within screen

Net heat window · 0.55 kJ/mm to 1.15 kJ/mm on an efficiency-adjusted basis.

Result details

Net heat input0.883 kJ/mm
Electrical arc energy1.103 kJ/mm
Thermal efficiency80 %
Arc power6.35 kW
Energy used for check0.883 kJ/mm
Solid steel wire feed (mass)4.58 kg/h
Estimated net wire deposition4.21 kg/h
Entered window minimum0.55 kJ/mm
Entered window maximum1.15 kJ/mm
Distance to nearest bound0.267 kJ/mm

Worked example

Starting inputs

Arc voltage
27 V
Arc current
235 A
Travel speed
345 mm/min
Wire diameter
1.2 mm
Wire feed speed
8.6 m/min
Minimum energy
0.55 kJ/mm
Maximum energy
1.15 kJ/mm

Baseline results

Net heat input
0.883 kJ/mm
Electrical arc energy
1.103 kJ/mm
Thermal efficiency
80 %
Arc power
6.35 kW

With 6.35 kW at 345 mm/min travel, electrical arc energy is 1.103 kJ/mm. The 80 % process factor gives 0.883 kJ/mm of net heat input.

Try it. Increasing travel speed reduces kJ/mm. The thermal factor remains fixed for the selected process.

Calculation method

Arc energy = 60P / v · Net heat input = η × 60P / v

Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.

Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.