WeldMetalLab

ASME IX · EN 1011-1

Low heat input for a GTAW root

A small root bead uses GTAW and a relatively fast manual travel estimate. Test whether net energy falls below the entered floor.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Arc parameters
V
A
mm/min
WPS limits
kJ/mm
kJ/mm

Live weld sheet

Updated from inputs
Arc and weld poolNet heat input 0.262 kJ/mm. Electrical arc energy 0.437 kJ/mm. Thermal efficiency 60 %. Arc power 1.06 kW NET HEAT0.262kJ/mmARC ENERGY0.437kJ/mmTHERMAL EFF.60%ARC POWER1.06kW ARC AND WELD POOL Travel 145 mm/minArc 0.437 kJ/mmGTAW NET HEAT WINDOWFAIL
Outside screen

Net heat window · 0.3 kJ/mm to 0.8 kJ/mm on an efficiency-adjusted basis.

Result details

Net heat input0.262 kJ/mm
Electrical arc energy0.437 kJ/mm
Thermal efficiency60 %
Arc power1.06 kW
Energy used for check0.262 kJ/mm
Solid steel wire feed (mass)—
Estimated net wire deposition—
Entered window minimum0.3 kJ/mm
Entered window maximum0.8 kJ/mm
Distance to nearest bound-0.038 kJ/mm

Worked example

Starting inputs

Welding process
GTAW
Arc voltage
12 V
Arc current
88 A
Travel speed
145 mm/min
Minimum energy
0.3 kJ/mm
Maximum energy
0.8 kJ/mm

Baseline results

Net heat input
0.262 kJ/mm
Electrical arc energy
0.437 kJ/mm
Thermal efficiency
60 %
Arc power
1.06 kW

With 1.06 kW at 145 mm/min travel, electrical arc energy is 0.437 kJ/mm. The 60 % process factor gives 0.262 kJ/mm of net heat input.

Try it. Reducing travel can raise heat input above the floor. Any production change still needs to fit the qualified procedure.

Calculation method

Arc energy = 60P / v · Net heat input = η × 60P / v

Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.

Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.

References

More worked examples