WeldMetalLab

ASME IX · EN 1011-1

Slow SMAW travel above the WPS ceiling

A slow manual pass is screened against the existing net heat ceiling before a procedure review.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Arc parameters
V
A
mm/min
WPS limits
kJ/mm
kJ/mm

Live weld sheet

Updated from inputs
Arc and weld poolNet heat input 2.283 kJ/mm. Electrical arc energy 2.854 kJ/mm. Thermal efficiency 80 %. Arc power 5 kW NET HEAT2.283kJ/mmARC ENERGY2.854kJ/mmTHERMAL EFF.80%ARC POWER5kW ARC AND WELD POOL Travel 105 mm/minArc 2.854 kJ/mmSMAW NET HEAT WINDOWFAIL
Outside screen

Net heat window · 0.65 kJ/mm to 1.55 kJ/mm on an efficiency-adjusted basis.

Result details

Net heat input2.283 kJ/mm
Electrical arc energy2.854 kJ/mm
Thermal efficiency80 %
Arc power5 kW
Energy used for check2.283 kJ/mm
Solid steel wire feed (mass)—
Estimated net wire deposition—
Entered window minimum0.65 kJ/mm
Entered window maximum1.55 kJ/mm
Distance to nearest bound-0.733 kJ/mm

Worked example

Starting inputs

Welding process
SMAW
Arc voltage
27 V
Arc current
185 A
Travel speed
105 mm/min
Minimum energy
0.65 kJ/mm
Maximum energy
1.55 kJ/mm

Baseline results

Net heat input
2.283 kJ/mm
Electrical arc energy
2.854 kJ/mm
Thermal efficiency
80 %
Arc power
5 kW

With 5 kW at 105 mm/min travel, electrical arc energy is 2.854 kJ/mm. The 80 % process factor gives 2.283 kJ/mm of net heat input.

Try it. Higher energy can slow the HAZ cooling cycle. Carry the efficiency-adjusted result into the t₈/₅ tool for that separate check.

Calculation method

Arc energy = 60P / v · Net heat input = η × 60P / v

Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.

Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.

References

More worked examples