ASME IX · EN 1011-1
Slow SMAW travel above the WPS ceiling
A slow manual pass is screened against the existing net heat ceiling before a procedure review.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsNet heat window · 0.65 kJ/mm to 1.55 kJ/mm on an efficiency-adjusted basis.
Result details
| Net heat input | 2.283 kJ/mm |
|---|---|
| Electrical arc energy | 2.854 kJ/mm |
| Thermal efficiency | 80 % |
| Arc power | 5 kW |
| Energy used for check | 2.283 kJ/mm |
| Solid steel wire feed (mass) | — |
| Estimated net wire deposition | — |
| Entered window minimum | 0.65 kJ/mm |
| Entered window maximum | 1.55 kJ/mm |
| Distance to nearest bound | -0.733 kJ/mm |
Worked example
Starting inputs
- Welding process
- SMAW
- Arc voltage
- 27 V
- Arc current
- 185 A
- Travel speed
- 105 mm/min
- Minimum energy
- 0.65 kJ/mm
- Maximum energy
- 1.55 kJ/mm
Baseline results
- Net heat input
- 2.283 kJ/mm
- Electrical arc energy
- 2.854 kJ/mm
- Thermal efficiency
- 80 %
- Arc power
- 5 kW
With 5 kW at 105 mm/min travel, electrical arc energy is 2.854 kJ/mm. The 80 % process factor gives 2.283 kJ/mm of net heat input.
Try it. Higher energy can slow the HAZ cooling cycle. Carry the efficiency-adjusted result into the t₈/₅ tool for that separate check.
Calculation method
Arc energy = 60P / v · Net heat input = η × 60P / v
Use P in kW and travel v in mm/min for kJ/mm. Electrical power comes from V × I / 1,000 or from measured mean instantaneous V × I during the run. For waveform-controlled welding, use the acquisition method required by the governing procedure.
Planning thermal factors are SAW 1.00, GMAW/FCAW/SMAW 0.80 and GTAW 0.60. Use WPS bounds expressed on the same basis as the selected result. Wire figures use a solid-steel equivalent of 7,850 kg/m³. Tubular wire needs measured linear mass for a production estimate.