WeldMetalLab

AWS D1.1 · EN 1011-2

H16 diffusible hydrogen sensitivity

The same mill chemistry is reviewed with an H16 consumable instead of a lower-hydrogen class.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Mill chemistry · mass %
%
%
%
%
%
%
%
%
%
%
Preheat conditions
mm
Record the combined heat path for fit-up review. Method B uses governing plate thickness below.
mm
kJ/mm
%
Enter zero if unknown.
MPa
°C
°C

Live weld sheet

Updated from inputs
Preheated plate sectionIIW carbon equivalent 0.436 %. Ito–Bessyo Pcm 0.258 %. Yurioka CEN 0.427 %. Preheat screening minimum 148 °C CE(IIW)0.436%PCM0.258%CEN0.427%PREHEAT MIN148°C PREHEATED PLATE SECTION HAZH16 · diffusible HPlate 31 mmH16 PREHEAT FLOORFAIL
Outside screen

Preheat floor · 105 °C working temperature vs 148 °C minimum.

Result details

IIW carbon equivalent0.436 %
Ito–Bessyo Pcm0.258 %
Yurioka CEN0.427 %
Preheat screening minimum148 °C
Base-metal CET0.31 %
Controlling CET0.31 %
Diffusible hydrogen input16 mL/100 g
IIW weldability bandElevated
Combined heat-path input58 mm
Raw Method B estimate148 °C
Minimum interpass screen148 °C
Working temperature margin-43 °C

Worked example

Starting inputs

Combined thickness
58 mm
Governing plate
31 mm
Hydrogen class
H16
Net heat input
1.1 kJ/mm
Specified WPS minimum
40 °C
Working temperature
105 °C

Baseline results

IIW carbon equivalent
0.436 %
Ito–Bessyo Pcm
0.258 %
Yurioka CEN
0.427 %
Preheat screening minimum
148 °C

Use controlling CET 0.31 %, a 31 mm plate and 16 mL/100 g diffusible hydrogen. The Method B result is 148 °C and the entered WPS minimum is 40 °C. The higher value sets the screening floor.

Try it. Change H16 to H4. The estimated minimum changes while each chemistry index remains fixed.

Calculation method

Tₚ = 697·CET + 160·tanh(d/35) + 62·HD⁰·³⁵ + (53·CET − 32)·Q − 328

CE(IIW) = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15. Pcm = C + Si/30 + (Mn + Cu + Cr)/20 + Ni/60 + Mo/15 + V/10 + 5B. CEN = C + [0.75 + 0.25 tanh(20(C − 0.12))]·[Si/24 + Mn/6 + Cu/15 + Ni/20 + (Cr + Mo + V + Nb)/5 + 5B].

The EN 1011-2 Method B screen uses CET = C + (Mn + Mo)/10 + (Cr + Cu)/20 + Ni/40. When supplied, weld-metal CET plus 0.03 is checked against base-metal CET. Method B uses governing plate thickness, separate from the recorded combined thickness. Published model limits are CET 0.20–0.50, plate 10–90 mm, Q 0.5–4 kJ/mm and yield up to 1,000 MPa.

The preheat and interpass floors are the higher of the model result and the entered WPS minimum. The IIW bands at 0.40 and 0.50 are qualitative. Verify procedure assumptions, grade-specific limits, restraint, acceptable upper interpass temperature and the governing AWS requirements.

References

More worked examples