WeldMetalLab

AWS D1.1 · EN 1011-2

Thick column plate with H8 consumables

A two-inch column plate meets a matching plate in a heavily built connection. Both pieces contribute to the recorded heat path.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Mill chemistry · mass %
%
%
%
%
%
%
%
%
%
%
Preheat conditions
in
Record the combined heat path for fit-up review. Method B uses governing plate thickness below.
in
kJ/in
%
Enter zero if unknown.
ksi
°F
°F

Live weld sheet

Updated from inputs
Preheated plate sectionIIW carbon equivalent 0.492 %. Ito–Bessyo Pcm 0.296 %. Yurioka CEN 0.498 %. Preheat screening minimum 336.7 °F CE(IIW)0.492%PCM0.296%CEN0.498%PREHEAT MIN336.7°F PREHEATED PLATE SECTION HAZH8 · diffusible HPlate 2 inH8 PREHEAT FLOORFAIL
Outside screen

Preheat floor · 199.4 °F working temperature vs 336.7 °F minimum.

Result details

IIW carbon equivalent0.492 %
Ito–Bessyo Pcm0.296 %
Yurioka CEN0.498 %
Preheat screening minimum336.7 °F
Base-metal CET0.354 %
Controlling CET0.354 %
Diffusible hydrogen input8 mL/100 g
IIW weldability bandElevated
Combined heat-path input4 in
Raw Method B estimate336.7 °F
Minimum interpass screen336.7 °F
Working temperature margin-137.3 °F

Worked example

Starting inputs

Carbon · C
0.19 %
Manganese · Mn
1.38 %
Chromium · Cr
0.2 %
Combined thickness
4 in
Governing plate
2 in
Hydrogen class
H8
Net heat input
40.64 kJ/in

Baseline results

IIW carbon equivalent
0.492 %
Ito–Bessyo Pcm
0.296 %
Yurioka CEN
0.498 %
Preheat screening minimum
336.7 °F

Use controlling CET 0.354 %, a 2 in plate and 8 mL/100 g diffusible hydrogen. The Method B result is 336.7 °F and the entered WPS minimum is 150 °F. The higher value sets the screening floor.

Try it. Use governing plate thickness for Method B. A recorded temperature below the derived floor calls for a procedure review.

Calculation method

Tₚ = 697·CET + 160·tanh(d/35) + 62·HD⁰·³⁵ + (53·CET − 32)·Q − 328

CE(IIW) = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15. Pcm = C + Si/30 + (Mn + Cu + Cr)/20 + Ni/60 + Mo/15 + V/10 + 5B. CEN = C + [0.75 + 0.25 tanh(20(C − 0.12))]·[Si/24 + Mn/6 + Cu/15 + Ni/20 + (Cr + Mo + V + Nb)/5 + 5B].

The EN 1011-2 Method B screen uses CET = C + (Mn + Mo)/10 + (Cr + Cu)/20 + Ni/40. When supplied, weld-metal CET plus 0.03 is checked against base-metal CET. Method B uses governing plate thickness, separate from the recorded combined thickness. Published model limits are CET 0.20–0.50, plate 10–90 mm, Q 0.5–4 kJ/mm and yield up to 1,000 MPa.

The preheat and interpass floors are the higher of the model result and the entered WPS minimum. The IIW bands at 0.40 and 0.50 are qualitative. Verify procedure assumptions, grade-specific limits, restraint, acceptable upper interpass temperature and the governing AWS requirements.

References

More worked examples