WeldMetalLab

API 1104 · ASME B31.3

NPS 2 Schedule 40 GTAW girth weld

A small shop spool has a thin Schedule 40 wall and a GTAW sequence with the dedicated hot pass omitted.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Pipe & preparation
°
in
in
%
Passes & cycle
lb/in³
in²
in
in/min
in/min
in/min
min
min

Live weld sheet

Updated from inputs
Girth-weld groove sectionDeposited filler per joint 0.042 lb. Estimated passes 2. Joint arc time 4.03 min. Total joint cycle 10.03 min NET FILLER0.042lbPASS COUNT2ARC TIME4.03minJOINT CYCLE10.03min GIRTH-WELD GROOVE SECTION Wall 0.154 inR1 · H0 · F0 · C1NPS 2 CYCLE TIME BUDGETPASS
Pass · within screen

Cycle time budget · 10.03 min planned vs 15 min budget.

Result details

Deposited filler per joint0.042 lb
Estimated passes2
Joint arc time4.03 min
Total joint cycle10.03 min
Effective wall0.154 in
Pipe outside diameter2.375 in
Pipe bore2.067 in
Groove centroid circumference7.1 in
Outside circumference7.46 in
Root circumference6.49 in
Groove mouth width0.223 in
Uncapped groove section0.019 in²
Groove and cap volume0.15 in³
Filler purchase per joint0.044 lb
Root passes1
Hot passes0
Fill passes0
Cap beads1
Cycle time margin4.97 min

Worked example

Starting inputs

Nominal pipe size
NPS 2
Wall source
Schedule 40
Primary included angle
70 °
Root opening
0.062598 in
Root land
0.03937 in
Overall filler process
GTAW
Dedicated hot pass
Skip hot pass

Baseline results

Deposited filler per joint
0.042 lb
Estimated passes
2
Joint arc time
4.03 min
Total joint cycle
10.03 min

The 0.019 in² groove runs around a 7.1 in centroid circumference before cap allowance. The sequence adds 1 root, 0 hot, 0 fill and 1 cap passes over 4.03 min of arc time.

Try it. The root travels on the bore circumference. The cap travels on the larger outside circumference.

Calculation method

V = ∫ 2πr·w(r)dr + A꜀·π·OD · Arc time = Σ pass length / travel speed

The model integrates the piecewise linear groove width at each radius. Cap reinforcement is a percentage of groove area revolved at the outside diameter. Schedule presets cover a subset of common B36.10 walls. Confirm actual wall and ovality at the joint.

Reserve one root pass and an optional hot pass. Cap beads must cover the groove mouth and deposit the entered extra cap area. Root, hot and cap allowances are 0.60, 0.75 and 0.80 times the entered fill area per pass. Apply the unused cap-bead area to the groove, then round up the remaining fill passes. Root, hot/fill and cap times use the root, centroid and outside circumferences.

Cycle time adds the entered fit-up, interpass and handling allowance. Actual pass placement, reinforcement profile, deposition rates and essential variables come from the qualified procedure.

References

More worked examples