A 3.4 ac catchment is 62% paved or roofed. The rest is lawn. A smooth HDPE barrel at 1.25% is screened against the estimated peak.
Estimate
Estimated peak runoff
- The barrel screen assumes steady full flow. A culvert design also checks inlet control, tailwater, headwater, debris and outlet conditions.
- Peak runoff · US gallons
- 3,957.4 US gpm
- Composite runoff coefficient
- 0.677
- Preliminary nominal pipe
- 18 in
- Theoretical full-flow diameter
- 15.69 in
- Selected barrel capacity
- 12.7222 ft³/s
- Full-flow velocity
- 7.199 ft/s
- Peak flow ÷ full area
- 4.989 ft/s
Download
Working this example
Starting estimate 8.8171 ft³/sEstimated peak runoff
Use the drainage area reaching the inlet and confirm where roof drains actually discharge. Check inlet and outlet control separately.
Questions & answers
What composite C comes from 62% hard cover and the remaining lawn?
0.62 × 0.92 + 0.38 × 0.28 gives a composite runoff coefficient of 0.6768.
Why use a local intensity for this parking catchment?
Local intensity varies with return period, storm duration and location. Use the criteria for this inlet and its tributary area.