Stormwater Rational Method Runoff & Culvert Pipe Sizing Calculator
Estimate peak runoff with a weighted C coefficient, then screen circular HDPE, CMP or RCP barrel diameter and flow velocity.
Estimate
- The barrel screen assumes steady full flow. A culvert design also checks inlet control, tailwater, headwater, debris and outlet conditions.
- Peak runoff · US gallons
- 2,737.2 US gpm
- Composite runoff coefficient
- 0.54
- Preliminary nominal pipe
- 15 in
- Theoretical full-flow diameter
- 13.2 in
- Selected barrel capacity
- 8.5704 ft³/s
- Full-flow velocity
- 6.984 ft/s
- Peak flow ÷ full area
- 4.969 ft/s
Download
How the estimate works
Weight the cover types by area
Multiply each runoff coefficient by its share of catchment area. Add the weighted terms to obtain composite C. Use local rainfall intensity for the chosen return period and time of concentration.
Estimate peak discharge
Use Q = C × i × A in consistent units. With in/h and acres, the exact depth-area conversion gives 1.00833 × C × i × A in ft³/s. The customary shortcut uses 1.0.
Screen a circular pipe
Use Manning full-flow capacity with hydraulic radius D ÷ 4 and the entered barrel slope. The tool chooses the first nominal size with enough computed capacity. Confirm actual inside diameter, availability and inlet and outlet performance.
References
Questions & answers
How do I combine pavement and lawn runoff coefficients?
Weight each coefficient by its fraction of the total drainage area. Add both products for an area-weighted coefficient.
Does a full-flow Manning diameter settle the culvert size?
It screens barrel capacity. A complete culvert design also evaluates inlet control, tailwater, allowable headwater, debris, outlet erosion and local criteria.
Which rainfall intensity belongs in the Rational Method?
Select the intensity for the design return period and a duration equal to the catchment time of concentration, using local rainfall data.