Worked example

Culvert velocity screen at a shallow grade

A low-gradient swale crosses under a light-duty lane. The RCP barrel check uses only 0.1% fall and compares full-flow velocity with a screening band.

Inputs

Measurement system
ac
in/h
Use local intensity for the design return period and time of concentration.
%
CATCHMENT TO CULVERTIllustrative runoff path to a circular culvert. Pipe capacity is screened at full flow. CATCHMENT TO CULVERT C 0.45 · 0.6 acØ 12 in · slope 0.1%Peak 0.653 ft³/s

Estimate

Estimated peak runoff
0.6534 ft³/s
  • Full-bore velocity falls outside the 2.5–10 ft/s screening band. Review sediment and outlet protection criteria.
  • The barrel screen assumes steady full flow. A culvert design also checks inlet control, tailwater, headwater, debris and outlet conditions.
Peak runoff · US gallons
293.3 US gpm
Composite runoff coefficient
0.45
Preliminary nominal pipe
12 in
Theoretical full-flow diameter
10.32 in
Selected barrel capacity
0.9764 ft³/s
Full-flow velocity
1.243 ft/s
Peak flow ÷ full area
0.832 ft/s
Download

Working this example

Starting estimate 0.6534 ft³/sEstimated peak runoff

Compare actual flow depth, sediment load and maintenance access before choosing pipe size or slope.

See the calculator formulas and assumptions

Questions & answers

Why can the shallow-grade pipe meet capacity and still raise a velocity flag?

Capacity measures discharge. A comparatively large flow area on a flat slope can carry the flow at a low mean velocity.

Is peak flow divided by full pipe area the actual shallow-grade outlet velocity?

It is a comparison using the full area. Actual outlet velocity depends on the hydraulic control and wetted area.