ControlLoopLab
Home Step responseWorked example

Lightly damped compliant stage

A lightweight positioning stage has visible ringing following a small reference step.

Model inputs

System model
rad/s

Closed-loop step & s-plane poles

Underdamped
Damping ζ
0.13
Overshoot
66.239%
2% settling
0.64783s
Bandwidth
69.082rad/s
Second-order step and pole mapStep to unit setpointoutput00.2020.4050.6070.81−0.1330.511.151.79Time (s)Pole locationsjω (rad/s)−19.1−10.6−2.186.2614.7−54.4−27.2027.254.4σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
45rad/s
Damped frequency ωd
44.618rad/s
Damping ratio ζ
0.13
Peak time
0.070411s
Overshoot
66.239%
2% settling time
0.64783s
5% settling time
0.50343s
10–90% rise time
0.025162s
Resonant peak
3.8791×
−3 dB bandwidth
69.082rad/s
Pole 1 real
−5.85rad/s
Pole 1 imaginary
44.618rad/s
Pole 2 real
−5.85rad/s
Pole 2 imaginary
−44.618rad/s

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.