ControlLoopLab
Home Step responseWorked example

Gimbal position at critical damping

A gimbal controller is approximated by a critically damped two-pole response for a smooth pointing step.

Model inputs

System model
rad/s

Closed-loop step & s-plane poles

Critically damped
Damping ζ
1
Overshoot
0%
2% settling
0.34317s
Bandwidth
10.941rad/s
Second-order step and pole mapStep to unit setpointoutput00.1070.2140.3220.429−0.080.3070.6931.08Time (s)Pole locationsjω (rad/s)−20.7−14.2−7.57−0.9855.6−20.7−10.4010.420.7σ (rad/s)Setpoint±2% corridorPoles (×)
T(s) = ωn² / (s² + 2ζωn s + ωn²)

Calculated results

Natural frequency ωn
17rad/s
Damped frequency ωd
0rad/s
Damping ratio ζ
1
Peak time
∞s
Overshoot
0%
2% settling time
0.34317s
5% settling time
0.27905s
10–90% rise time
0.19752s
Resonant peak
1×
−3 dB bandwidth
10.941rad/s
Pole 1 real
−17rad/s
Pole 1 imaginary
0rad/s
Pole 2 real
−17rad/s
Pole 2 imaginary
0rad/s

Model and interpretation

Full methodology

Use the matching damping regime

The unity-gain model has conjugate poles for 0 ≤ ζ < 1, a repeated real pole at ζ = 1 and two distinct real poles for ζ > 1. For an underdamped step, overshoot is 100 exp(−πζ/√(1−ζ²)).

Separate first crossing from last crossing

Rise time uses the first 10% and 90% crossings. Settling uses the last exit from each band. An undamped response has no finite settling time. For an extremely large number of oscillations the settling result approaches the exponential envelope at display precision.

Synthesize and recheck

Synthesis uses the standard 4/(ζωn) approximation to target 2% settling. Inspect the exact recalculated settling time and bandwidth before transferring a target to a real controller.